HVAC, Plumbing & Electrical in Versailles, KY | GreenBox
Emergency Service
<p>Unforeseen HVAC or plumbing issues can disrupt your comfort at times. Our Emergency Service guarantees swift attention. Day or night, reach out for immediate resolution, ensuring your home or business stays comfortable and functional, providing you with peace of mind around the clock. Give us a call at (859) 278-0281.</p>

Reliable Home Service Experts in Versailles, KY

 

Versailles Service Overview

  • Local Priority: We engineer targeted heating, cooling, plumbing, electrical, and indoor air quality solutions optimized for the unique, sprawling architectural landscape of Versailles.
  • Certified Expertise: Our local technicians possess the specialized training required to manage complex infrastructure across historic downtown homes, Falling Springs subdivisions, and expansive Woodford County horse farms featuring detached guest quarters, workshops, and barns.
  • Efficiency Focus: From balancing multi-zone HVAC setups to protecting farm facilities with backup power configurations, we focus on lowering your seasonal utility costs and securing absolute mechanical reliability.

 

Versailles is not like most Kentucky communities. While many cities are defined by subdivisions and commercial corridors, Versailles is defined by Horse Country. Historic homes near Downtown Versailles share the landscape with world-renowned horse farms, estate properties, rolling pastures, and some of the most recognizable scenery in the Bluegrass.

From the roads leading to Woodford Reserve to the countryside surrounding The Kentucky Castle, homeownership here often looks very different than it does elsewhere in Central Kentucky.

That difference matters when it comes to heating, cooling, plumbing, and electrical systems. A service call at a historic home near Downtown Versailles is rarely the same as one on a multi-building property outside town.

GreenBox Heating & Air helps homeowners throughout Versailles and Woodford County maintain, repair, and modernize the systems that keep their homes comfortable, efficient, and reliable

Contact GreenBox Heating & Air at (859) 278-0281 to schedule an appointment with our team.

what to do when your ac stops working

 

Homeownership In Horse Country Comes With Unique Demands

Versailles homeowners often care for properties that don’t fit into a standard mold. Some families live in historic homes that have evolved through generations of renovations. Others own homes in neighborhoods like Falling Springs, Merewood, and Huntertown where major systems are beginning to reach replacement age.

Beyond the city limits, many residents maintain larger properties with detached garages, guest houses, barns, workshops, and outbuildings that require additional planning and maintenance.

Because GreenBox serves homes throughout Versailles and Woodford County every day, our technicians understand how those differences influence everything from HVAC performance to electrical capacity and water distribution.

 

“These guys worked together very well to correct the problem without delay. Very focused. I have employed these plumbers before, so when I have a need I know who to call.”

— Bobby T.

 

Plumbing Systems Often Extend Far Beyond The Main House

In many communities, plumbing begins and ends at the home. In Versailles, that’s not always the case. Larger properties frequently include detached structures, barns, workshops, guest quarters, and outdoor living spaces that all depend on reliable water service. Even within town, historic homes near Downtown Versailles often contain layers of plumbing upgrades completed over several decades.

Homeowners throughout Versailles commonly contact GreenBox because they’re dealing with:

  • Water heaters that can no longer keep pace with household demand
  • Aging plumbing systems in historic homes
  • Water quality concerns affecting larger rural properties
  • Hidden leaks causing damage beneath floors and behind walls
  • Drain and sewer issues disrupting daily routines
  • Gas line installations for outdoor kitchens, fireplaces, and modern appliances

Whether we’re troubleshooting a tankless water heater near Falling Springs or helping maintain plumbing infrastructure on a larger Woodford County property, our goal is always the same: provide solutions that perform reliably for years to come.

Whether you need an emergency plumber in versailles ky for a clogged sewer line or are looking for an expert water heater replacement in versailles ky to handle your household demand, GreenBox is ready to help. Schedule Your Expert Plumbing Service Now or call (859) 278-0281

 

Heating Challenges Vary From Historic Homes To Estate Properties

A furnace serving a historic home near Downtown Versailles faces different demands than a heating system responsible for a large custom home overlooking horse farms. Ceiling heights, additions, insulation levels, and property size all influence how effectively a heating system performs.

Throughout Versailles, homeowners often reach out because they’re experiencing:

  • Rising heating costs during colder months
  • Uneven temperatures throughout the home
  • Aging furnaces approaching replacement age
  • Heat pumps losing efficiency over time
  • Frequent repairs on older equipment
  • Comfort challenges in larger or expanded homes

From Huntertown to Clover Bottom, GreenBox helps homeowners evaluate their systems, improve efficiency, and make informed decisions about repairs and replacements.

From specialized furnace repair in versailles ky for historic downtown homes to energy-saving heat pump replacement in versailles ky for newer suburban layouts, our local technicians ensure your property stays warm and energy-efficient all season long. Call us at (859) 278-0281 

 

“We were very impressed with the professionalism and thoroughness of the HVAC service we received. Our technician, Matt Tibbitts, was excellent. His attention to detail, pleasant demeanor, and knowledge of our units were greatly appreciated.”

— Andrew C.

Solving Versailles Home Issues 

Problem: Larger custom properties, historic downtown estates, and multi-structure horse farms regularly experience uneven temperatures, soaring energy bills, and second floors that remain uncomfortably hot during the summer.

Solution: GreenBox installs customized multi-zone HVAC configurations, high-efficiency ductless mini-splits for detached additions, and tailored airflow adjustments to maintain even comfort across large footprints.


Problem: Plumbing systems in Woodford County often extend far beyond the main house, leaving detached guest houses, workshops, and barns vulnerable to hidden structural leaks, dropping water pressure, and failing water heaters.

Solution: Our experienced local plumbers specialize in complex utility routing, precision leak detection, and advanced tankless water heater installations to keep water flowing reliably throughout your entire property.


Problem: Extensive estate properties, gate systems, outdoor living spaces, and barns place heavy strain on older electrical panels, leaving expensive equipment and smart networks vulnerable to severe central Kentucky storm surges.

Solution: Licensed GreenBox electricians provide code-compliant electrical panel upgrades, whole-property backup generator installations, and robust surge protection networks to keep critical farm and home infrastructure running safely.

 

Cooling Large Homes Requires More Than Bigger Equipment

One of the biggest misconceptions about cooling is that larger homes simply need larger air conditioners. In reality, comfort often depends on zoning, airflow, humidity control, insulation, and system design. This is especially true throughout Versailles, where custom homes, estate properties, and renovated historic residences are common.

Many homeowners call GreenBox because they’re dealing with:

  • Air conditioners running constantly during summer weather
  • Humidity problems that leave the home feeling uncomfortable
  • Second floors that remain warmer than lower levels
  • High cooling costs despite newer equipment
  • Older systems struggling to keep up with demand
  • Detached spaces that benefit from ductless mini-split solutions

Whether we’re helping a homeowner near the Bluegrass Scenic Railroad or servicing a property surrounded by open pastureland, our cooling recommendations are tailored to the way the property is actually used.

Whether you need emergency ac repair in versailles ky for an estate property, routine seasonal cooling maintenance in Falling Springs, or a high-efficiency ductless mini-split installation for a detached space, GreenBox provides fast, reliable solutions. Call (859) 278-0281 

“We were very impressed with the professionalism and thoroughness of the HVAC service we received. Our technician, Matt Tibbitts, was excellent. His attention to detail, pleasant demeanor, and knowledge of our units were greatly appreciated.”

— Andrew C.

 

Electrical Panel Upgrades, EV Chargers & E

Reliable Power Matters More When Your Property Does More

Electrical systems in Versailles often support far more than a single residence. Detached garages, workshops, barns, gate systems, landscape lighting, outdoor entertainment areas, and agricultural facilities all place additional demands on electrical infrastructure.

Wiring and Rewiring in Lexington KY

GreenBox regularly helps homeowners address concerns such as:

  • Electrical panels that no longer support growing power demands
  • Aging wiring in older homes and renovated properties
  • EV charger installations for current and future vehicles
  • Whole-home surge protection for sensitive equipment
  • Generator systems protecting homes and outbuildings during outages
  • Electrical capacity upgrades for expanding properties

For many Woodford County homeowners, backup power is more than a convenience. It helps protect families, equipment, security systems, refrigeration, and other critical operations when severe weather impacts utility service.

If you are experiencing tripped breakers or need a code-compliant electrical panel upgrade in versailles ky, an EV charging station setup, or a whole-home backup generator configuration, turn to a trusted electrician in versailles ky. Book Your Safe Electrical Service Today or call (859) 278-0281

 

Indoor Air Quality Is Influenced By Life In The Bluegrass

The same open spaces that make Versailles beautiful can also influence indoor air quality. Horse farms, open fields, mature trees, seasonal pollen, agricultural activity, and Kentucky humidity all affect the air inside local homes.

Common concerns we hear from homeowners include:

  • Seasonal allergies that seem worse indoors
  • Dust accumulation despite frequent cleaning
  • Excess humidity during summer months
  • Uneven airflow throughout the home
  • Lingering odors and stale indoor air
  • Energy loss caused by insulation deficiencies

Whether a home sits near Downtown Versailles or on acreage outside town, GreenBox helps homeowners create cleaner, healthier indoor environments through customized air quality solutions.

Take control of your environment and improve your health by scheduling professional duct cleaning, whole-home air purification, or a customized home air quality assessment with the top hvac versailles ky specialists. Request a Home Air Quality Assessment or call (859) 278-0281

Why Versailles Chooses GreenBox

    •  
  • True Local Knowledge: Complete familiarity with the distinct structural challenges found throughout Merewood, Huntertown, and the agricultural acreage surrounding The Kentucky Castle and Woodford Reserve.
  •  
  • The GreenBox Care Plan: Our proactive preventative program catches minor technical flaws before they turn into major emergency failures. 

  • Honest, Pressure-Free Advice: We provide direct diagnostic insights and transparent, upfront pricing, ensuring you receive the exact repair or installation your property needs with zero high-pressure sales pitches.
  •  
  • Our Rewarding Referral Program: We believe the highest compliment we can receive is a recommendation to a neighbor. When you share your positive GreenBox experience with fellow homeowners in Versailles, our referral program rewards you with cash-back bonuses.

 

Your Trusted Home Service Team In Versailles

Whether you’re maintaining a historic property near Downtown Versailles, upgrading systems in Falling Springs, improving comfort in Huntertown, or caring for a horse farm residence in Woodford County, GreenBox Heating & Air is ready to help.

Our team provides customized plumbing, heating, cooling, electrical, and indoor air quality solutions designed specifically for the homes, properties, and lifestyle that make Versailles one of Kentucky’s most distinctive communities. Contact GreenBox Heating & Air at (859) 278-0281 or schedule your appointment online today.

Versailles Homeowners FAQs

In large custom homes and historic properties common to Woodford County, standard cooling systems often struggle to distribute air evenly, leaving second stories too warm and utility bills high. True comfort relies on precise airflow design, specialized zoning, and proper humidity control rather than just a larger unit. GreenBox specializes in customized multi-zone HVAC systems and ductless mini-split solutions designed for large, expanded, or multi-building layouts.

Unlike standard suburban lots, Versailles properties frequently feature plumbing infrastructure that extends far beyond the main house to supply detached garages, guest quarters, barns, and outdoor spaces. These expanded systems are highly susceptible to hidden underground leaks, water quality issues, and water heater strain. GreenBox delivers advanced tankless water heater options and comprehensive utility line maintenance to keep water running smoothly across your acreage.

For many local homeowners and farm operators, backup power is an absolute necessity to protect critical operations during severe central Kentucky weather. A whole-home generator system safeguards your family, security gates, agricultural facilities, refrigeration, and sensitive equipment during unexpected utility outages. Our licensed electricians evaluate your full property layout to install a perfectly sized backup power solution.

Enrolling your Versailles property in our preventative Care Plan preserves your system warranties and intercepts technical issues before they become expensive emergencies. 

Page Updated July 6, 2-026

Recent Jobs and Reviews in Versailles, KY

Job Locations and Reviews

Completed Care Plan maintenance on dual mini-split system including basement heat pump/air handler unit and upstairs mini-split. Performed comprehensive tune-up procedures, cleaned and washed all washable filters on both units, verified system operation with digital meter readings showing 25°F temperature differential, and measured electrical amperage at 5.49A on outdoor condensing unit. Inspected Aprilaire whole house humidifier installation and confirmed all HVAC components operating within manufacturer specifications.
Completed Care Plan maintenance on dual mini-split system including basement heat pump/air handler unit and upstairs mini-split. Performed comprehensive tune-up procedures, cleaned and washed all washable filters on both units, verified system operation with digital meter readings showing 25°F temperature differential, and measured electrical amperage at 5.49A on outdoor condensing unit. Inspected Aprilaire whole house humidifier installation and confirmed all HVAC components operating within manufacturer specifications.
Carter B.
Carter B. Checked in
Completed Care Plan maintenance on dual mini-split system including basement heat pump/air handler unit and upstairs mini-split. Performed comprehensive tune-up procedures, cleaned and washed all washable filters on both units, verified system operation with digital meter readings showing 25°F temperature differential, and measured electrical amperage at 5.49A on outdoor condensing unit. Inspected Aprilaire whole house humidifier installation and confirmed all HVAC components operating within manufacturer specifications.
Versailles, KY 40383
Replaced defective thermal expansion valve (TXV) on air conditioning system under parts warranty. Recovered and reused existing refrigerant from the system, installed new TXV, and added AC Renew product to enhance system performance and longevity. Connected manifold gauges and diagnostic equipment to verify proper refrigerant pressures and system operation following the repair. Total service time was approximately 4 hours to complete the warranty repair work.
Replaced defective thermal expansion valve (TXV) on air conditioning system under parts warranty. Recovered and reused existing refrigerant from the system, installed new TXV, and added AC Renew product to enhance system performance and longevity. Connected manifold gauges and diagnostic equipment to verify proper refrigerant pressures and system operation following the repair. Total service time was approximately 4 hours to complete the warranty repair work.
Matt B.
Matt B. Checked in
Replaced defective thermal expansion valve (TXV) on air conditioning system under parts warranty. Recovered and reused existing refrigerant from the system, installed new TXV, and added AC Renew product to enhance system performance and longevity. Connected manifold gauges and diagnostic equipment to verify proper refrigerant pressures and system operation following the repair. Total service time was approximately 4 hours to complete the warranty repair work.
Versailles, KY 40383
Completed full residential heat pump system installation including Bryant 2-ton outdoor heat pump unit (model GH5SAN52400A), Bryant 2-ton air handler (model FJ5ANXB24L00), and Bryant 10 kW electric heat kit (model TU-EC-10BKB) with digital thermostat. Installed outdoor unit pad with snow legs, electrical whip kit, and disconnect box for code-compliant power supply. Applied refrigerant line insulation and installed refrigerant line filter for system protection. Added foil duct wrap to insulate exposed sections of supply ductwork where deterioration was evident. Configured air handler with condensate trap, SS2 coil drain safety water sensor, and ceiling saver overflow drain pan with secondary water sensor for leak protection. Fabricated transition connections to integrate with existing ductwork system and installed standard-sized air filter rack. Removed and disposed of existing HVAC equipment per regulations. Pulled all applicable permits and completed installation to current code requi
Completed full residential heat pump system installation including Bryant 2-ton outdoor heat pump unit (model GH5SAN52400A), Bryant 2-ton air handler (model FJ5ANXB24L00), and Bryant 10 kW electric heat kit (model TU-EC-10BKB) with digital thermostat. Installed outdoor unit pad with snow legs, electrical whip kit, and disconnect box for code-compliant power supply. Applied refrigerant line insulation and installed refrigerant line filter for system protection. Added foil duct wrap to insulate exposed sections of supply ductwork where deterioration was evident. Configured air handler with condensate trap, SS2 coil drain safety water sensor, and ceiling saver overflow drain pan with secondary water sensor for leak protection. Fabricated transition connections to integrate with existing ductwork system and installed standard-sized air filter rack. Removed and disposed of existing HVAC equipment per regulations. Pulled all applicable permits and completed installation to current code requi
Gideon J.
Gideon J. Checked in
Completed full residential heat pump system installation including Bryant 2-ton outdoor heat pump unit (model GH5SAN52400A), Bryant 2-ton air handler (model FJ5ANXB24L00), and Bryant 10 kW electric heat kit (model TU-EC-10BKB) with digital thermostat. Installed outdoor unit pad with snow legs, electrical whip kit, and disconnect box for code-compliant power supply. Applied refrigerant line insulation and installed refrigerant line filter for system protection. Added foil duct wrap to insulate exposed sections of supply ductwork where deterioration was evident. Configured air handler with condensate trap, SS2 coil drain safety water sensor, and ceiling saver overflow drain pan with secondary water sensor for leak protection. Fabricated transition connections to integrate with existing ductwork system and installed standard-sized air filter rack. Removed and disposed of existing HVAC equipment per regulations. Pulled all applicable permits and completed installation to current code requi
Versailles, KY 40383
# HVAC Maintenance - Club Single - Comm

Performed comprehensive preventive maintenance on commercial HVAC system consisting of two air conditioning units and two gas furnace units (167-177). Conducted standard Care Plan tune-up procedures including inspection of all electrical control boards, relay systems, and wiring connections. Verified proper operation of control modules with heat sink cooling fins and examined terminal block connections with multi-colored circuit wiring. Inspected circuit board components including relays, capacitors, and low-voltage control circuits. Documented system conditions through photographic evidence showing control board assembly, wiring harnesses, and blower motor components. 

Following completion of maintenance procedures, units experienced operational failure requiring immediate attention. Systems are currently non-functional and flagged as possible recall situation. Customer provides own filtration media. Further diagnostic work and corrective acti
# HVAC Maintenance - Club Single - Comm

Performed comprehensive preventive maintenance on commercial HVAC system consisting of two air conditioning units and two gas furnace units (167-177). Conducted standard Care Plan tune-up procedures including inspection of all electrical control boards, relay systems, and wiring connections. Verified proper operation of control modules with heat sink cooling fins and examined terminal block connections with multi-colored circuit wiring. Inspected circuit board components including relays, capacitors, and low-voltage control circuits. Documented system conditions through photographic evidence showing control board assembly, wiring harnesses, and blower motor components. 

Following completion of maintenance procedures, units experienced operational failure requiring immediate attention. Systems are currently non-functional and flagged as possible recall situation. Customer provides own filtration media. Further diagnostic work and corrective acti
Carter B.
Carter B. Checked in
# HVAC Maintenance - Club Single - Comm Performed comprehensive preventive maintenance on commercial HVAC system consisting of two air conditioning units and two gas furnace units (167-177). Conducted standard Care Plan tune-up procedures including inspection of all electrical control boards, relay systems, and wiring connections. Verified proper operation of control modules with heat sink cooling fins and examined terminal block connections with multi-colored circuit wiring. Inspected circuit board components including relays, capacitors, and low-voltage control circuits. Documented system conditions through photographic evidence showing control board assembly, wiring harnesses, and blower motor components. Following completion of maintenance procedures, units experienced operational failure requiring immediate attention. Systems are currently non-functional and flagged as possible recall situation. Customer provides own filtration media. Further diagnostic work and corrective acti
Versailles, KY 40383
Responded to service call regarding water leakage from wall-mounted ductless mini-split system causing visible damage to interior walls and ceiling. Upon arrival, confirmed active moisture issue with dark vertical staining running down wall beneath unit and water marks present on ceiling. Inspected mini-split installation and identified condensate drainage problem requiring immediate attention to prevent further water damage to building structure.
Responded to service call regarding water leakage from wall-mounted ductless mini-split system causing visible damage to interior walls and ceiling. Upon arrival, confirmed active moisture issue with dark vertical staining running down wall beneath unit and water marks present on ceiling. Inspected mini-split installation and identified condensate drainage problem requiring immediate attention to prevent further water damage to building structure.
Jayden C.
Jayden C. Checked in
Responded to service call regarding water leakage from wall-mounted ductless mini-split system causing visible damage to interior walls and ceiling. Upon arrival, confirmed active moisture issue with dark vertical staining running down wall beneath unit and water marks present on ceiling. Inspected mini-split installation and identified condensate drainage problem requiring immediate attention to prevent further water damage to building structure.
Versailles, KY 40383
Conducted follow-up inspection of geothermal loop system to verify pressure stability after water was added during previous monthly maintenance visit. Inspected HeatMaster circulation equipment and monitored system pressure using installed gauge, which maintained stable readings with no indication of pressure loss or active leaks in the hydronic loop.
Conducted follow-up inspection of geothermal loop system to verify pressure stability after water was added during previous monthly maintenance visit. Inspected HeatMaster circulation equipment and monitored system pressure using installed gauge, which maintained stable readings with no indication of pressure loss or active leaks in the hydronic loop.
Carter B.
Carter B. Checked in
Conducted follow-up inspection of geothermal loop system to verify pressure stability after water was added during previous monthly maintenance visit. Inspected HeatMaster circulation equipment and monitored system pressure using installed gauge, which maintained stable readings with no indication of pressure loss or active leaks in the hydronic loop.
Versailles, KY 40383
Responded to no-cooling call on 9-year-old upstairs AC unit that had previously been quoted for UV light installation. Upon arrival, performed diagnostic inspection of the system and documented exterior condition of equipment showing weathering and normal wear patterns. Inspected internal wiring compartments and electrical connections, capturing photos of panel surfaces and internal wiring bundles for service records.
Responded to no-cooling call on 9-year-old upstairs AC unit that had previously been quoted for UV light installation. Upon arrival, performed diagnostic inspection of the system and documented exterior condition of equipment showing weathering and normal wear patterns. Inspected internal wiring compartments and electrical connections, capturing photos of panel surfaces and internal wiring bundles for service records.
Carter B.
Carter B. Checked in
Responded to no-cooling call on 9-year-old upstairs AC unit that had previously been quoted for UV light installation. Upon arrival, performed diagnostic inspection of the system and documented exterior condition of equipment showing weathering and normal wear patterns. Inspected internal wiring compartments and electrical connections, capturing photos of panel surfaces and internal wiring bundles for service records.
Versailles, KY 40383
Removed existing mini split system including outdoor unit and indoor wall mount heads. Installed new Friedrich 3-ton two-zone outdoor unit (FPHMR36A3D) on wall bracket at different location per homeowner request, utilizing existing electrical connection. Mounted two Friedrich 18K BTU indoor wall mount units (FAHFW18A3D) on different walls as specified by homeowner. Installed new line sets and drain lines to both indoor heads. System tested and operational upon completion.
Removed existing mini split system including outdoor unit and indoor wall mount heads. Installed new Friedrich 3-ton two-zone outdoor unit (FPHMR36A3D) on wall bracket at different location per homeowner request, utilizing existing electrical connection. Mounted two Friedrich 18K BTU indoor wall mount units (FAHFW18A3D) on different walls as specified by homeowner. Installed new line sets and drain lines to both indoor heads. System tested and operational upon completion.
Vance P.
Vance P. Checked in
Removed existing mini split system including outdoor unit and indoor wall mount heads. Installed new Friedrich 3-ton two-zone outdoor unit (FPHMR36A3D) on wall bracket at different location per homeowner request, utilizing existing electrical connection. Mounted two Friedrich 18K BTU indoor wall mount units (FAHFW18A3D) on different walls as specified by homeowner. Installed new line sets and drain lines to both indoor heads. System tested and operational upon completion.
Versailles, KY 40383
Responded to no-cool complaint on 12-year-old residential air conditioning system with inadequate cooling performance (thermostat set to 76°F but only reaching 79°F). Upon inspection, found outdoor condensing unit and indoor air handler with aged flexible ductwork showing significant dust accumulation and insulation wear in attic installation. Performed system diagnostics including temperature differential measurements, refrigerant pressure checks, and airflow assessment. Identified reduced cooling capacity consistent with system age and potential airflow restrictions from deteriorated duct insulation. Cleaned condenser coils, checked refrigerant charge levels, inspected electrical connections at both indoor and outdoor units, and verified proper thermostat operation. System restored to optimal performance within manufacturer specifications for equipment age. Recommended monitoring system performance and considering future replacement planning given unit's 12-year service life approach
Responded to no-cool complaint on 12-year-old residential air conditioning system with inadequate cooling performance (thermostat set to 76°F but only reaching 79°F). Upon inspection, found outdoor condensing unit and indoor air handler with aged flexible ductwork showing significant dust accumulation and insulation wear in attic installation. Performed system diagnostics including temperature differential measurements, refrigerant pressure checks, and airflow assessment. Identified reduced cooling capacity consistent with system age and potential airflow restrictions from deteriorated duct insulation. Cleaned condenser coils, checked refrigerant charge levels, inspected electrical connections at both indoor and outdoor units, and verified proper thermostat operation. System restored to optimal performance within manufacturer specifications for equipment age. Recommended monitoring system performance and considering future replacement planning given unit's 12-year service life approach
Andrew W.
Andrew W. Checked in
Responded to no-cool complaint on 12-year-old residential air conditioning system with inadequate cooling performance (thermostat set to 76°F but only reaching 79°F). Upon inspection, found outdoor condensing unit and indoor air handler with aged flexible ductwork showing significant dust accumulation and insulation wear in attic installation. Performed system diagnostics including temperature differential measurements, refrigerant pressure checks, and airflow assessment. Identified reduced cooling capacity consistent with system age and potential airflow restrictions from deteriorated duct insulation. Cleaned condenser coils, checked refrigerant charge levels, inspected electrical connections at both indoor and outdoor units, and verified proper thermostat operation. System restored to optimal performance within manufacturer specifications for equipment age. Recommended monitoring system performance and considering future replacement planning given unit's 12-year service life approach
Versailles, KY 40383
Responded to no cooling complaint on heat pump system located in laundry room. Performed diagnostic testing on air handler unit using infrared thermometer and multimeter to measure supply air temperature and verify electrical component operation. Supply air temperature measured at 65°F, indicating insufficient cooling capacity. Conducted electrical diagnostics at control board, measuring microamp readings at 5.28 to verify proper signal communication between components. Inspected wiring connections, control module, and relay operation within equipment panel. System evaluation completed with diagnostic findings documented for recommended repairs.
Responded to no cooling complaint on heat pump system located in laundry room. Performed diagnostic testing on air handler unit using infrared thermometer and multimeter to measure supply air temperature and verify electrical component operation. Supply air temperature measured at 65°F, indicating insufficient cooling capacity. Conducted electrical diagnostics at control board, measuring microamp readings at 5.28 to verify proper signal communication between components. Inspected wiring connections, control module, and relay operation within equipment panel. System evaluation completed with diagnostic findings documented for recommended repairs.
Andrew W.
Andrew W. Checked in
Responded to no cooling complaint on heat pump system located in laundry room. Performed diagnostic testing on air handler unit using infrared thermometer and multimeter to measure supply air temperature and verify electrical component operation. Supply air temperature measured at 65°F, indicating insufficient cooling capacity. Conducted electrical diagnostics at control board, measuring microamp readings at 5.28 to verify proper signal communication between components. Inspected wiring connections, control module, and relay operation within equipment panel. System evaluation completed with diagnostic findings documented for recommended repairs.
Versailles, KY 40383
Completed full residential geothermal system installation featuring a WaterFurnace 3.5-ton 5 Series two-stage package unit (model W5AV042BD1A12CTR2B00) configured as vertical with right return, achieving 30 EER and 5 COP efficiency ratings. Installed FC2-FPT two-pump flow center with hose kit to manage ground loop circulation, integrated hot water de-superheater for domestic water heating, and mounted 10kW auxiliary heat kit for supplemental heating capacity. Connected system components using CK4LI unit connection kit and MA4SWV adapter to ensure proper interface between geothermal unit and flow center. Installed TPCC32U03WWFI WaterFurnace digital thermostat for system control and monitoring. Routed and secured copper refrigerant lines through wall cavities with proper spacing and mounting hardware, installing insulation to prevent condensation and energy loss. Completed all electrical connections for unit, flow center pumps, heat kit, and thermostat per manufacturer specifications and
Completed full residential geothermal system installation featuring a WaterFurnace 3.5-ton 5 Series two-stage package unit (model W5AV042BD1A12CTR2B00) configured as vertical with right return, achieving 30 EER and 5 COP efficiency ratings. Installed FC2-FPT two-pump flow center with hose kit to manage ground loop circulation, integrated hot water de-superheater for domestic water heating, and mounted 10kW auxiliary heat kit for supplemental heating capacity. Connected system components using CK4LI unit connection kit and MA4SWV adapter to ensure proper interface between geothermal unit and flow center. Installed TPCC32U03WWFI WaterFurnace digital thermostat for system control and monitoring. Routed and secured copper refrigerant lines through wall cavities with proper spacing and mounting hardware, installing insulation to prevent condensation and energy loss. Completed all electrical connections for unit, flow center pumps, heat kit, and thermostat per manufacturer specifications and
Matt T.
Matt T. Checked in
Completed full residential geothermal system installation featuring a WaterFurnace 3.5-ton 5 Series two-stage package unit (model W5AV042BD1A12CTR2B00) configured as vertical with right return, achieving 30 EER and 5 COP efficiency ratings. Installed FC2-FPT two-pump flow center with hose kit to manage ground loop circulation, integrated hot water de-superheater for domestic water heating, and mounted 10kW auxiliary heat kit for supplemental heating capacity. Connected system components using CK4LI unit connection kit and MA4SWV adapter to ensure proper interface between geothermal unit and flow center. Installed TPCC32U03WWFI WaterFurnace digital thermostat for system control and monitoring. Routed and secured copper refrigerant lines through wall cavities with proper spacing and mounting hardware, installing insulation to prevent condensation and energy loss. Completed all electrical connections for unit, flow center pumps, heat kit, and thermostat per manufacturer specifications and
Versailles, KY 40383
Installed dedicated 120V duplex receptacle outlet in unfinished utility area to provide power for dual water shut-off valves servicing two water heaters. Mounted outlet box on exposed wall framing and ran electrical cable from power source to new outlet location. Completed installation per specifications with all wiring properly secured to structural members.
Installed dedicated 120V duplex receptacle outlet in unfinished utility area to provide power for dual water shut-off valves servicing two water heaters. Mounted outlet box on exposed wall framing and ran electrical cable from power source to new outlet location. Completed installation per specifications with all wiring properly secured to structural members.
Logan P.
Logan P. Checked in
Installed dedicated 120V duplex receptacle outlet in unfinished utility area to provide power for dual water shut-off valves servicing two water heaters. Mounted outlet box on exposed wall framing and ran electrical cable from power source to new outlet location. Completed installation per specifications with all wiring properly secured to structural members.
Versailles, KY 40383
Responded to non-urgent service call for upstairs attic HVAC system with reported UV light electrical failure. Upon inspection, discovered UV light wiring was fried, likely due to improper installation by previous contractor. Documented existing conditions with photographs showing heavily contaminated evaporator coil with significant dust, dirt, and biological growth accumulation that has severely restricted airflow capacity. System requires UV light replacement with proper wiring installation and comprehensive coil cleaning to restore efficient operation. Provided quote for necessary repairs and maintenance work.
Responded to non-urgent service call for upstairs attic HVAC system with reported UV light electrical failure. Upon inspection, discovered UV light wiring was fried, likely due to improper installation by previous contractor. Documented existing conditions with photographs showing heavily contaminated evaporator coil with significant dust, dirt, and biological growth accumulation that has severely restricted airflow capacity. System requires UV light replacement with proper wiring installation and comprehensive coil cleaning to restore efficient operation. Provided quote for necessary repairs and maintenance work.
Andrew W.
Andrew W. Checked in
Responded to non-urgent service call for upstairs attic HVAC system with reported UV light electrical failure. Upon inspection, discovered UV light wiring was fried, likely due to improper installation by previous contractor. Documented existing conditions with photographs showing heavily contaminated evaporator coil with significant dust, dirt, and biological growth accumulation that has severely restricted airflow capacity. System requires UV light replacement with proper wiring installation and comprehensive coil cleaning to restore efficient operation. Provided quote for necessary repairs and maintenance work.
Versailles, KY 40383
Completed preventive maintenance tune-up on dual air conditioning and gas furnace systems per club membership agreement. Performed comprehensive inspection of outdoor Carrier AC unit, verified electrical connections at meter panel, tested system amperage draw at 12.3A and voltage at acceptable levels, and inspected capacitor operation. Customer provides their own air filters for these units.
Completed preventive maintenance tune-up on dual air conditioning and gas furnace systems per club membership agreement. Performed comprehensive inspection of outdoor Carrier AC unit, verified electrical connections at meter panel, tested system amperage draw at 12.3A and voltage at acceptable levels, and inspected capacitor operation. Customer provides their own air filters for these units.
Carter B.
Carter B. Checked in
Completed preventive maintenance tune-up on dual air conditioning and gas furnace systems per club membership agreement. Performed comprehensive inspection of outdoor Carrier AC unit, verified electrical connections at meter panel, tested system amperage draw at 12.3A and voltage at acceptable levels, and inspected capacitor operation. Customer provides their own air filters for these units.
Versailles, KY 40383
Responded to service call for Generac whole-house generator displaying red indicator light that had previously shown green status. Upon arrival, performed comprehensive diagnostic evaluation of the generator system and associated electrical components. Inspected the generator control panel, verified all electrical connections at the exterior-mounted Generac transfer switch and metering equipment, and assessed the overall installation integrity. Checked generator battery voltage, control board status indicators, and examined all visible wiring conduits for damage or loose connections. Evaluated the fuel supply system and confirmed proper grounding of the unit. Documented current system status with photographic evidence showing the exterior electrical installation including the transfer switch mounted on brick exterior wall and associated utility connections. Provided customer with diagnostic findings and recommended next steps for restoring generator to normal operational status with gr
Responded to service call for Generac whole-house generator displaying red indicator light that had previously shown green status. Upon arrival, performed comprehensive diagnostic evaluation of the generator system and associated electrical components. Inspected the generator control panel, verified all electrical connections at the exterior-mounted Generac transfer switch and metering equipment, and assessed the overall installation integrity. Checked generator battery voltage, control board status indicators, and examined all visible wiring conduits for damage or loose connections. Evaluated the fuel supply system and confirmed proper grounding of the unit. Documented current system status with photographic evidence showing the exterior electrical installation including the transfer switch mounted on brick exterior wall and associated utility connections. Provided customer with diagnostic findings and recommended next steps for restoring generator to normal operational status with gr
Trent E.
Trent E. Checked in
Responded to service call for Generac whole-house generator displaying red indicator light that had previously shown green status. Upon arrival, performed comprehensive diagnostic evaluation of the generator system and associated electrical components. Inspected the generator control panel, verified all electrical connections at the exterior-mounted Generac transfer switch and metering equipment, and assessed the overall installation integrity. Checked generator battery voltage, control board status indicators, and examined all visible wiring conduits for damage or loose connections. Evaluated the fuel supply system and confirmed proper grounding of the unit. Documented current system status with photographic evidence showing the exterior electrical installation including the transfer switch mounted on brick exterior wall and associated utility connections. Provided customer with diagnostic findings and recommended next steps for restoring generator to normal operational status with gr
Versailles, KY 40383
Installed two 50-gallon Bradford White electric water heaters in parallel configuration in utility room with exposed stud walls. Completed all necessary plumbing connections using copper pipe and PEX tubing with brass fittings, installed three safety shut-off valves for system isolation and emergency protection, and connected electrical supply via conduit to junction box. Verified proper operation of both units and ensured all connections met code requirements.
Installed two 50-gallon Bradford White electric water heaters in parallel configuration in utility room with exposed stud walls. Completed all necessary plumbing connections using copper pipe and PEX tubing with brass fittings, installed three safety shut-off valves for system isolation and emergency protection, and connected electrical supply via conduit to junction box. Verified proper operation of both units and ensured all connections met code requirements.
Caddo D.
Caddo D. Checked in
Installed two 50-gallon Bradford White electric water heaters in parallel configuration in utility room with exposed stud walls. Completed all necessary plumbing connections using copper pipe and PEX tubing with brass fittings, installed three safety shut-off valves for system isolation and emergency protection, and connected electrical supply via conduit to junction box. Verified proper operation of both units and ensured all connections met code requirements.
Versailles, KY 40383
Responded to service call for HVAC system running continuously with thermostat displaying "waiting for equipment" message in auto mode. Accessed outdoor Lennox ML17XC1S condensing unit via deck hatch to perform diagnostic evaluation. Documented equipment specifications and current system operation, photographed unit nameplate showing R-454B refrigerant system manufactured February 2025. Troubleshot communication issue between thermostat and outdoor unit causing improper cycling behavior.
Responded to service call for HVAC system running continuously with thermostat displaying "waiting for equipment" message in auto mode. Accessed outdoor Lennox ML17XC1S condensing unit via deck hatch to perform diagnostic evaluation. Documented equipment specifications and current system operation, photographed unit nameplate showing R-454B refrigerant system manufactured February 2025. Troubleshot communication issue between thermostat and outdoor unit causing improper cycling behavior.
Andrew W.
Andrew W. Checked in
Responded to service call for HVAC system running continuously with thermostat displaying "waiting for equipment" message in auto mode. Accessed outdoor Lennox ML17XC1S condensing unit via deck hatch to perform diagnostic evaluation. Documented equipment specifications and current system operation, photographed unit nameplate showing R-454B refrigerant system manufactured February 2025. Troubleshot communication issue between thermostat and outdoor unit causing improper cycling behavior.
Versailles, KY 40383
Responded to no cooling complaint on 5-year-old Trane air conditioning unit located in upstairs bathroom mechanical closet. Upon arrival, performed diagnostic inspection of system including air handler, ductwork, and condensate drain lines. Inspected vertical HVAC equipment installation, examined heat exchanger coil assembly, and verified proper mounting and connections of all components. Documented system configuration with metallic insulated ductwork, black PVC condensate piping with multiple couplings, and electrical conduit routing. System evaluated and customer advised of findings.
Responded to no cooling complaint on 5-year-old Trane air conditioning unit located in upstairs bathroom mechanical closet. Upon arrival, performed diagnostic inspection of system including air handler, ductwork, and condensate drain lines. Inspected vertical HVAC equipment installation, examined heat exchanger coil assembly, and verified proper mounting and connections of all components. Documented system configuration with metallic insulated ductwork, black PVC condensate piping with multiple couplings, and electrical conduit routing. System evaluated and customer advised of findings.
Andrew W.
Andrew W. Checked in
Responded to no cooling complaint on 5-year-old Trane air conditioning unit located in upstairs bathroom mechanical closet. Upon arrival, performed diagnostic inspection of system including air handler, ductwork, and condensate drain lines. Inspected vertical HVAC equipment installation, examined heat exchanger coil assembly, and verified proper mounting and connections of all components. Documented system configuration with metallic insulated ductwork, black PVC condensate piping with multiple couplings, and electrical conduit routing. System evaluated and customer advised of findings.
Versailles, KY 40383
Verified and documented electrical service source for office space per landlord's request to confirm power origin. Inspected interior electrical panel labeled "Doctor" with associated conduit runs and exterior ground-level junction box with circuit protection devices. Photographically documented that office power is supplied from dedicated new service installation rather than museum electrical system, confirming independent electrical service to the office space.
Verified and documented electrical service source for office space per landlord's request to confirm power origin. Inspected interior electrical panel labeled "Doctor" with associated conduit runs and exterior ground-level junction box with circuit protection devices. Photographically documented that office power is supplied from dedicated new service installation rather than museum electrical system, confirming independent electrical service to the office space.
Ted K.
Ted K. Checked in
Verified and documented electrical service source for office space per landlord's request to confirm power origin. Inspected interior electrical panel labeled "Doctor" with associated conduit runs and exterior ground-level junction box with circuit protection devices. Photographically documented that office power is supplied from dedicated new service installation rather than museum electrical system, confirming independent electrical service to the office space.
Versailles, KY 40383
Completed routine maintenance on heat pump and air handler system located in attic space. Performed electrical diagnostics using digital multimeter, verifying voltage readings and system performance parameters. Inspected refrigerant lines, connections, and overall equipment condition, with customer providing their own filters for the service visit.
Completed routine maintenance on heat pump and air handler system located in attic space. Performed electrical diagnostics using digital multimeter, verifying voltage readings and system performance parameters. Inspected refrigerant lines, connections, and overall equipment condition, with customer providing their own filters for the service visit.
Carter B.
Carter B. Checked in
Completed routine maintenance on heat pump and air handler system located in attic space. Performed electrical diagnostics using digital multimeter, verifying voltage readings and system performance parameters. Inspected refrigerant lines, connections, and overall equipment condition, with customer providing their own filters for the service visit.
Versailles, KY 40383

Why GreenBox?

We Pride Ourselves On Friendly, Honest Customer Service

Craftsmanship Guaranteed

We will do what it takes to ensure your satisfaction with the quality of your installation.

Emergency Service

Our team is available around the clock for your heating and air conditioning emergencies.

Upfront Pricing

You will know the cost of your service before we start any work.

365-Day Guarantee

If a system installed by us doesn't meet your needs after one year, we will refund you 100%.

Same-Day Installation

We can install your new heating or cooling system in as little as one day.

Free In-Home Estimate

We want your service to be easy and convenient, so we offer free estimates.

Craftsmanship Guaranteed

We will do what it takes to ensure your satisfaction with the quality of your installation.

Emergency Service

Our team is available around the clock for your heating and air conditioning emergencies.

Upfront Pricing

You will know the cost of your service before we start any work.

365-Day Guarantee

If a system installed by us doesn't meet your needs after one year, we will refund you 100%.

Same-Day Installation

We can install your new heating or cooling system in as little as one day.

Free In-Home Estimate

We want your service to be easy and convenient, so we offer free estimates.

Review Image

What Our Clients Are Saying

Talk about quality service! These guys and gals are the best! I have their yearly service plan and it is well worth it. They are professional, friendly and tidy. They do such great work. I am customer for life. Braden came out today and was speedy…

Regina S.

Regina S.

They were able to send David out the day I called. He was very professional, polite, and was able to educate me on our issues. He was able to give us an on the spot quote and it was very much to my surprise a lot…

Adrienne F.

Adrienne F.

Glad I went with GreenBox! They were able to get me scheduled immediately and fixed up same day. Matt was helpful and easy to talk to. Will recommend and use again!

Theresa W.

Theresa W.

Great customer service and value. The technician Robert Caudill called ahead of time as requested and did a great job. Would definitely recommend GreenBox to anyone needing service or sales!

Chad M.

Chad M.

Love GreenBox!! Always professional. Very knowledgeable. Hard working, fair, courteous, clean and just good!

Kelly S.

Kelly S.