The plumbing in your Lexington, KY, home is its backbone. From hot showers to moving waste away from your home, you need it to work to keep your home functioning. The team at GreenBox Home Services is ready to help you with all your plumbing needs. Let us show you our commitment to customer service and quality work. We offer same-day service, upfront pricing, and financing options.
Why Choose GreenBox Home Services?
GreenBox Home Services is ready to help regardless of your problem. Our fully licensed, insured, and certified team has the skills and experience to solve your plumbing issue. We’re dedicated to building relationships through exceptional customer service, attention to detail, and affordable pricing. We back our work with our Quality of Service Guarantee. You can trust we’ll do the job right the first time. Call GreenBox Home Services at (859) 278-0281 or contact us online to schedule an appointment for any of your plumbing needs.
Same-Day Plumbing Repair in Lexington
When you need reliable plumbing repairs in Lexington, look no further than GreenBox Home Services. We’re the area experts in full-service plumbing solutions. Our services include:
- Bathroom repairs
- Kitchen repairs
- Leak detections and repairs
- Sewer line repairs
- Water service line repairs
- Faucet repairs
For superior plumbing repair services in Lexington, choose GreenBox Home Services. Call us at (859) 278-0281 or contact us online today!
Expert Plumbing Installation in Lexington
If you need plumbing installation services in Lexington, our experts are ready to help! Their skills and experience mean your new plumbing will be beautiful and functional. Count on us for:
- Faucets: If you want to change the aesthetic or replace a broken fixture, we can help you!
- Sinks: A cracked sink is unsightly and can allow water to leak. Let us get your sink functioning again.
- Garbage Disposals: Keep kitchen waste from collecting with a garbage disposal. We’ll help you choose one that fits your needs and home.
- Plumbing Systems: It doesn’t matter if you need to redo a small section of your plumbing or a whole-house repiping. We will get the job done right the first time.
To schedule your plumbing installation service, call us at (859) 278-0281 or contact us online today!
Reliable Water Heaters
A working water heater is more than a luxury. You need it to work to clean your home and family. If you need water heater services in Lexington, we offer a full range of services, including:
- Tankless water heaters
- Instant water heaters
- Water heater replacement
- Water heater repair
- Water heater maintenance
Let us help you with your water heater needs in Lexington. Call GreenBox Home Services at (859) 278-0281 or contact us online to schedule your appointment.
Other Services
Part of keeping your Lexington home running smoothly is keeping all your plumbing systems working well. GreenBox Home Services is the area’s premier full-service plumbing company and offers solutions to all your plumbing needs. Our other services include:
For comprehensive plumbing services in Lexington, choose GreenBox Home Services. We’re ready to help you solve all your plumbing problems, both small and large! Call us at (859) 278-0281 or contact us online to schedule your appointment today!
Plumbing FAQs
Which type of water heater is most popular?
Traditional tank water heaters are still the most popular option for homeowners. Their various sizes and relatively low entry-point cost make them an affordable and reliable option.
Do plumbers fix drains?
Yes! Professional plumbers do fix drains. They have the skills, experience, and equipment to precisely locate the problem and clear the drain without damaging your drain and sewer lines.
Recent Jobs and Reviews in Lexington, KY
Job Locations and Reviews
Completed comprehensive Care Plan tune-up on dual HVAC system consisting of two air conditioning units and two gas furnaces located in attic and basement. Performed electrical diagnostics using clamp meter to verify proper amperage draw on outdoor condensing units, inspected capacitors, and documented system performance with detailed photos to ensure all equipment covered under the complimentary one-year Care Plan is operating within manufacturer specifications.
Responded to no cooling complaint on 2-year-old electric HVAC system that had been inoperative for several weeks. Performed diagnostic evaluation of indoor unit located in front door closet. Inspected thermostat operation showing 67°F display reading with system set to cooling mode, verified thermostat programming and control settings, and examined equipment nameplate specifications and safety labels on indoor unit.
Responded to no cooling complaint on 10-12 year old gas furnace/AC system with continuous fan operation. Upon arrival, found thermostat displaying "cool set at 75" with system calling for cooling. Performed diagnostic evaluation of outdoor condensing unit and indoor air handler located in basement with easy access. Inspected white condenser unit positioned on concrete pad against exterior brick wall, verified proper power supply from electrical junction box, and checked refrigerant lines and condensate drain routing through PVC piping. Examined programmable thermostat controls and verified settings, noting "check hum pad" and "check filter" indicators on display. Tested system operation including compressor engagement, fan cycling, and airflow delivery. Filter had been changed during previous maintenance visit. Identified root cause of continuous fan operation and inadequate cooling performance, distinguishing from previous maintenance inspection findings. Completed necessary repairs t
Responded to emergency water leak in basement bathroom. Upon inspection, identified leak originating from compromised plumbing connection near utility pump assembly. Isolated water supply using existing shut-off valve, repaired faulty connection, tested system for proper operation, and verified no additional leaks present before restoring full water service.
Responded to service call for HVAC system producing unusual noise and insufficient cooling with thermostat set to 70°F. Performed diagnostic inspection of outdoor condenser unit and indoor control board. Examined compressor operation, refrigerant line connections, and electrical components including PCB with integrated circuits and terminal connections. Identified operational issues affecting system performance and cooling capacity. Documented equipment condition with photographs of outdoor unit installation and control board wiring configuration for service records.
Completed annual care plan maintenance tune-up on Carrier heat pump system with air handler located in basement. Performed comprehensive inspection of indoor and outdoor equipment, verified thermostat operation showing 69°F actual temperature, inspected Mitsubishi Electric outdoor unit with dual fan configuration, checked electrical connections, tested system controls, and confirmed proper operation of all components. Customer provides their own 20x25x4 filter for routine replacement.
Completed preventive maintenance tune-up on heat pump and air handler system located in attic space. Performed comprehensive system diagnostics including electrical testing with capacitance readings showing 45.12 MFD on measured component. Inspected evaporator coil assembly and identified significant rust and corrosion present along coil frame seams and lower panel edges, with left side showing more extensive deterioration than right side. Coil fins remain intact and functional despite frame corrosion. Documented system condition with photos for service records. Customer providing their own filters for unit.
Completed kitchen drain repipe and installed customer-supplied fixture as specified. All plumbing connections secured with proper compression fittings, P-trap installed to code, and system tested for leaks with successful results.
Completed comprehensive preventive maintenance on Generac Evolution 2.0 air-cooled standby generator (Model G0072101, Serial 3012281620) with 48.1 run hours displayed on control panel. Performed full system inspection including physical unit condition assessment, fuel system verification, battery load testing, and high/low voltage electrical connection testing. Replaced spark plugs, air filter, and oil filter per manufacturer specifications. Inspected generator enclosure interior and exterior for debris, wear, and proper ventilation. Verified transfer system operation (Model 10000011659, Serial 3012349664) rated at 200 amps, 240 volts with all four AC circuit modules functioning correctly. Conducted complete system test in both manual and automatic modes under load to confirm proper operation and seamless transfer capability. All components operating within normal parameters upon completion.
Completed Gold Level prepaid maintenance on three air conditioning systems, three gas furnaces, and two humidifiers. Performed comprehensive tune-up procedures on all units including inspection, cleaning, and testing of components. Installed customer-supplied filters: two 16x25x1 and one 20x20x1. All three exterior condensing units were inspected and tested with refrigerant pressures verified using manifold gauges. Interior ductwork and attic-mounted equipment were accessed and inspected for proper operation. All systems operating within normal parameters upon completion of maintenance service.
Performed complete dryer vent cleaning service, removing significant accumulation of lint buildup from the exhaust system. Extracted large volume of compacted lint material that had created a blockage hazard, improving airflow and reducing fire risk. Installed new white plastic louvered vent cap with secure mounting to replace the existing deteriorated cover, ensuring proper exterior termination and protection against weather intrusion and pest entry.
Responded to low water pressure complaint in guest bathroom affecting sink and bathtub, with particulate material present in tub water. Inspected exposed plumbing infrastructure in basement area, examining supply lines, aging cast iron drainage pipes, and water distribution system. Identified sediment buildup and potential issues with galvanized piping contributing to reduced flow and water quality concerns. Documented existing plumbing configuration including copper supply lines, flexible connectors, and various pipe materials showing age-related deterioration that may be impacting water pressure and introducing particulates into the system.
Completed rebuild of drain assembly under kitchen sink to restore proper drainage function. Performed small section repipe above water heater, relocating PEX water lines away from exhaust flue to ensure safe clearance and compliance with code requirements. Work included installing new drain piping, fittings, and repositioning supply lines to eliminate potential heat exposure hazard from water heater exhaust vent.
Completed Care Plan tune-up on recently installed air conditioning unit and gas furnace system located in basement. Performed comprehensive maintenance inspection, verified proper operation of AC unit, and documented system performance with diagnostic measurements showing temperature readings of 59°F. Confirmed HomeVault Model 6 PLUS air quality device installation and operational status with active LED indicators. Customer will provide their own air filters for ongoing maintenance.
Responded to service call for Mitsubishi Electric ceiling cassette mini-split unit (MLZ-KP series) that was running continuously without cycling off. Upon arrival, inspected the ceiling-mounted air handler and verified constant operation. Reviewed unit specifications using manufacturer installation manual for models MLZ-KP09NA2, MLZ-KP12NA2, and MLZ-KP18NA2 to confirm proper operational parameters. Diagnosed thermostat control issue preventing system from reaching setpoint and shutting down compressor. System restored to normal cycling operation with proper on/off functionality.
Completed Gold Level prepaid maintenance on single-system residential HVAC unit with air handler located in attic requiring 10-foot ladder access through restricted opening. Performed comprehensive inspection and maintenance of outdoor condenser unit and indoor air handling components per maintenance agreement specifications, with customer-supplied filters installed during service.
Responded to no cooling complaint on 3-year-old electric commercial unit located in upstairs conference room ceiling. Upon arrival, confirmed system attempting to operate but failing to cool effectively for approximately two weeks. Performed diagnostic evaluation of electrical components and control circuit. Inspected contactor, capacitor, and associated wiring connections within control panel. Identified faulty contactor preventing proper compressor engagement. Replaced defective contactor and verified all electrical connections secure. Tested system operation through complete cooling cycle, confirmed proper amperage draw and temperature differential across evaporator coil. Unit now cooling properly and operating within manufacturer specifications.
Returned to address callback for toilet still leaking after previous service visit where Mansfield gasket, fill valve, and angle stop were replaced. Upon inspection, removed tank lid and diagnosed issue with internal tank components. Verified all connections were secure and tested flush mechanism and fill valve operation. Adjusted water level and confirmed toilet is now functioning properly with no leaks present at tank, bowl, or supply line connections.
Responded to no cooling complaint on commercial Ruud RTU unit. Upon arrival, confirmed with site contact that incorrect unit was initially diagnosed on previous day's service call. Located and inspected correct rooftop unit experiencing cooling issues. Performed diagnostic testing and temperature measurements using pipe clamp meter, recording supply air temperature of 85°F. Identified unit requires 20x20x4 filter replacement and documented filter size on equipment for future maintenance reference. Unit operational status and specific repair recommendations provided to customer for approval.
Completed Gold Level prepaid maintenance on two 9-year-old AC systems in a dual-zone residential property with units located in basement and second-floor closet. Performed comprehensive system diagnostics including electrical testing with clamp meter, which recorded 52.9 amp draw on outdoor condenser unit. Inspected capacitor, wiring connections, and electrical components for proper operation and signs of wear. Noted significant debris accumulation including dried leaves inside outdoor unit cabinet and excessive vegetation growth obstructing airflow around exterior condenser unit against brick wall. Cleaned accessible components and documented conditions requiring attention. Verified both systems operational. Customer providing their own filters for routine replacement.