Heating, Cooling, Plumbing & Electrical Services in Lexington, KY
Emergency Service
Unforeseen HVAC or plumbing issues can disrupt your comfort at times. Our Emergency Service guarantees swift attention. Day or night, reach out for immediate resolution, ensuring your home or business stays comfortable and functional, providing you with peace of mind around the clock. Give us a call at (859) 203-5124.
Emergency Service
Unforeseen HVAC or plumbing issues can disrupt your comfort at times. Our Emergency Service guarantees swift attention. Day or night, reach out for immediate resolution, ensuring your home or business stays comfortable and functional, providing you with peace of mind around the clock. Give us a call at (859) 203-5124.

Top-Rated Heating, Cooling in Lexington, KY

Plumbing & Electrical Services

 

Lexington Service Overview

  • Local Priority: We provide dedicated HVAC, plumbing, electrical, and indoor air quality support across the entire Lexington community.

  • Certified Expertise: Our technicians are highly trained to handle the unique infrastructure, historic home preservation needs, and seasonal climate swings of Fayette County homes.

  • Efficiency Focus: We specialize in optimizing your heating, cooling, and plumbing systems to ensure long-term, year-round comfort and reduced utility costs.

 

From the historic homes lining Richmond Road and the tree-lined streets of Chevy Chase to the growing neighborhoods around Hamburg, Masterson Station, and Citation Boulevard, Lexington homeowners rely on their home’s essential systems every day. GreenBox Heating & Air provides expert heating, cooling, plumbing, electrical, and indoor air quality services throughout Lexington, KY. 

Our team understands the unique needs of Central Kentucky homes, whether we’re working on a century-old property near Ashland Park, a ranch home in Gardenside, or a newer build off Man o’ War Boulevard.

Call (859) 203-5124 today to schedule service in Lexington.

Serving Lexington Homeowners Every Day

Lexington continues to grow, but many neighborhoods still feature homes built decades ago with aging plumbing, electrical, and HVAC systems. GreenBox Heating & Air works throughout Fayette County every day, helping homeowners near The Arboretum, Beaumont Centre, Tates Creek, and Downtown Lexington keep their homes safe, comfortable, and efficient.

Whether you’re dealing with an unexpected breakdown during a Kentucky cold snap or planning upgrades before summer arrives, our technicians bring local experience and dependable solutions to every job.

 

“I had a project in mind and it hinged on a natural gas line evaluation. Green Box promptly responded and Caddo Downs came yesterday to assess the situation. Caddo provided excellent feedback. GreenBox’s expertise and staff always lead me down the right path with a positive outcome. GreenBox is my go-to for plumbing, heating, air and electrical services.”

— Bridget S.

Plumbing Services in Lexington, KY

Plumbing issues can vary dramatically across Lexington. In neighborhoods like Kenwick, Bell Court, and Ashland Park, older water and drain lines often require repairs or replacement. In newer communities near Hamburg and Hartland, homeowners frequently call us for water heater upgrades, fixture installations, and water quality improvements.

Our Lexington plumbing team can help with:

  • Diagnosing hidden leaks before they cause damage to walls, flooring, or foundations
  • Clearing stubborn drain and sewer line blockages that disrupt daily routines
  • Repairing or replacing water heaters to ensure reliable hot water year-round
  • Upgrading aging pipes in older Lexington homes with modern plumbing materials
  • Installing gas lines for appliances, fireplaces, and outdoor living spaces
  • Improving water quality with filtration and treatment solutions designed for local households
  • Responding quickly to emergency plumbing situations throughout Fayette County

Whether you’re renovating a home near Woodland Park or dealing with a plumbing emergency off Nicholasville Road, GreenBox delivers solutions built to last.

Get Reliable Lexington Plumber Today by calling (859) 203-5124 or Schedule your Service Online!

Heating Services in Lexington, KY

Lexington winters can bring freezing temperatures, ice, and sudden weather swings that put heating systems to the test. Homes throughout neighborhoods like Chevy Chase and Fairway often rely on older furnaces or boiler systems, while many newer homes near Brannon Crossing and Hamburg utilize high-efficiency heat pumps.

Our heating services are designed to help Lexington homeowners:

  • Restore heat quickly when furnaces, boilers, or heat pumps stop working
  • Improve energy efficiency and lower winter utility costs
  • Replace aging heating equipment before costly breakdowns occur
  • Maintain reliable comfort through seasonal tune-ups and inspections
  • Upgrade older systems with modern, high-performance heating technology
  • Address uneven temperatures and comfort issues throughout the home
  • Prepare heating equipment for Kentucky’s unpredictable winter weather

From homes near Southland Drive to properties along Versailles Road, GreenBox helps keep Lexington families warm and comfortable all season long.

Restore Warmth Fast: Schedule Lexington Furnace or Boiler Repair!

 

“Jayden C. did a great job with our HVAC maintenance visit. We had questions about our thermostat and he was able to offer options for us to upgrade. He was on time and worked quickly. We’re always pleased with GreenBox Heating & Air!”

— Leo L.

Solving Lexington Home Issues 

Problem: An aging furnace or historic boiler is struggling to keep up with unpredictable Kentucky cold snaps, leading to uneven home temperatures and soaring winter utility bills.

Solution: We perform precision tune-ups, urgent system fixes, or high-efficiency furnace and heat pump installations to ensure your living spaces stay warm while keeping your monthly costs manageable.


Problem: Outdated electrical panels and aging wiring in older neighborhoods like Chevy Chase or Bell Court cannot safely support modern appliances, EV chargers, or smart home electronics.

Solution: Our licensed electricians provide comprehensive panel upgrades and code-compliant rewiring to safely meet the power demands of your growing household.


Problem: Hard water buildup, hidden pipe leaks, or slow drains are disrupting daily routines and threatening the structural safety of older Central Kentucky properties.

Solution: We deliver fast drain clearing, hidden leak diagnostics, and modern pipe replacements with premium materials built to last.

Air Conditioning Services in Lexington, KY

Anyone who has spent a summer in Lexington knows how quickly heat and humidity can make indoor spaces uncomfortable. When temperatures climb and humidity settles over the Bluegrass region, homeowners need cooling systems they can depend on.

Our cooling specialists help homeowners:

Whether you’re near Hamburg Pavilion, UK’s campus, or Veterans Park, GreenBox provides cooling solutions tailored to your home’s needs.

Book Professional AC Service Today by calling (859) 203-5124 

Electrical Services in Lexington, KY

Lexington’s housing market includes everything from historic homes with outdated wiring to newly constructed properties equipped with modern technology. As electrical demands continue to increase, many homeowners find their existing systems need upgrades to keep pace.

Electrical Installation in Lexington KY

Our electricians help Lexington homeowners:

Whether you’re updating a historic property near Downtown Lexington or adding new technology to a home in Hartland, our licensed electricians provide safe, code-compliant solutions.

Schedule Your Code-Compliant Electrical Inspection Today!

Lexington ZIP Codes We Serve

GreenBox Heating & Air proudly serves homeowners throughout Lexington and surrounding Fayette County communities.

We provide service throughout:

  • 40502
  • 40503
  • 40504
  • 40508
  • 40509
  • 40511
  • 40513
  • 40514
  • 40515
  • 40517

Whether you’re located near Downtown Lexington, Hamburg, Beaumont, Tates Creek, Masterson Station, Gardenside, or Chevy Chase, our team is ready to help!

 

“Outstanding support as always. We have counted on this company for years and truly grateful for their excellent work. All team members are so smart, considerate and dependable.”

— Lauren P.

Why Lexington Chooses GreenBox

  • Lexington homeowners expect exceptional service and local accountability from the companies they hire. Here is why your neighbors trust GreenBox Heating & Air:

Experienced Technicians: Skilled local professionals who understand the plumbing, HVAC, and electrical quirks of everything from historic properties near Ashland Park to new builds off Man o’ War Boulevard.

Clear, Honest Recommendations: No high-pressure sales or hidden surprises. We provide straightforward diagnostics and honest options tailored directly to your home’s layout and budget.

All-in-One Convenience: Complete expertise across plumbing, heating, cooling, electrical, and indoor air quality lines so you only have to make one reliable call to keep your home running smoothly.

Community Commitment: We work throughout Fayette County every day, bringing professional workmanship and a steadfast commitment to long-term home comfort and safety.

Schedule Service in Lexington, KY

Whether you need emergency plumbing repairs near Tates Creek, a furnace replacement in Chevy Chase, AC service in Hamburg, or electrical upgrades in Beaumont, GreenBox Heating & Air is ready to help. Our team proudly serves homeowners throughout Lexington with expert workmanship, responsive service, and solutions designed for Kentucky homes. From routine maintenance and system tune-ups to complex repairs and full equipment replacements, indoor air quality solutions– we provide the dependable support local homeowners need to keep their homes comfortable, safe, and efficient throughout every season.

 

 FAQs for Lexington Homeowners

In historic Lexington areas like Kenwick, Bell Court, and Ashland Park, plumbing emergencies are frequently caused by aging water lines, corroded sewer pipes, and stubborn root intrusions. Over time, these outdated materials weaken, leading to sudden hidden leaks, structural drain blockages, and low water pressure that require immediate professional diagnostics or pipe replacement.

Uneven temperatures are common in multi-story Central Kentucky homes, especially those with older furnaces or boilers. This issue is typically caused by restricted airflow, aging equipment struggling to maintain pressure, or a lack of modern zone-control systems. Upgrading to a high-efficiency heat pump or scheduling a seasonal heating tune-up can optimize airflow and lower winter utility costs.

Many historic homes in neighborhoods like Bell Court and Chevy Chase were built decades ago with electrical systems that cannot handle modern energy demands. As households add high-powered electronics, modern appliances, and EV chargers, these aging panels frequently overload, causing tripped breakers, flickering lights, and serious safety hazards. Upgrading to a modern electrical panel ensures code-compliant safety and provides stable, reliable power throughout your property.

Page Updated on June 29, 2026

Recent Jobs and Reviews in Lexington, KY

Lexington, KY at a glance

Greenbox Home Services has completed 20 jobs in Lexington, KY in July 2026.

The most recent job was on July 30, 2026.

Greenbox Home Services has completed 2,942 jobs in Lexington, KY in the last 12 months.

Job Locations and Reviews

Lexington, KY - Replaced defective blower motor and control board under parts warranty. Retrieved motor from Trane Supply and completed installation of both components to restore system operation.
Matt T.
Matt T. Checked in
Replaced defective blower motor and control board under parts warranty. Retrieved motor from Trane Supply and completed installation of both components to restore system operation.
Lexington, KY 40511
Lexington, KY - Completed Care Plan maintenance tune-up on two AC units and two gas furnace systems. Replaced air filters on both systems with 16x25x4 and 20x25x4 filters as included in the maintenance plan, servicing the attic unit accessed via closet and the garage unit. All equipment inspected and operating within normal parameters.
Jayden C.
Jayden C. Checked in
Completed Care Plan maintenance tune-up on two AC units and two gas furnace systems. Replaced air filters on both systems with 16x25x4 and 20x25x4 filters as included in the maintenance plan, servicing the attic unit accessed via closet and the garage unit. All equipment inspected and operating within normal parameters.
Lexington, KY 40515
Completed full HVAC system replacement including removal and disposal of existing equipment. Installed Bryant 70K BTU 80% efficiency gas furnace (model 800SB36070M17), Bryant 2.5 ton 15 SEER2 air conditioning unit (model CVAVA3017XMA), and Bryant evaporator coil (model GA5SAN53000W) with digital thermostat. Installation included outdoor unit pad, electrical whip kit, electrical disconnect box, 10 feet of insulated refrigerant line set, refrigerant line filter drier, transition from evaporator coil to existing ductwork, and SS2 coil drain safety water sensor. Obtained applicable permits, tested system operation, and enrolled equipment in annual maintenance care plan with semi-annual inspections. System covered by 1-year labor warranty, 10-year parts warranty, and 20-year heat exchanger warranty.
Completed full HVAC system replacement including removal and disposal of existing equipment. Installed Bryant 70K BTU 80% efficiency gas furnace (model 800SB36070M17), Bryant 2.5 ton 15 SEER2 air conditioning unit (model CVAVA3017XMA), and Bryant evaporator coil (model GA5SAN53000W) with digital thermostat. Installation included outdoor unit pad, electrical whip kit, electrical disconnect box, 10 feet of insulated refrigerant line set, refrigerant line filter drier, transition from evaporator coil to existing ductwork, and SS2 coil drain safety water sensor. Obtained applicable permits, tested system operation, and enrolled equipment in annual maintenance care plan with semi-annual inspections. System covered by 1-year labor warranty, 10-year parts warranty, and 20-year heat exchanger warranty.
Vance P.
Vance P. Checked in
Completed full HVAC system replacement including removal and disposal of existing equipment. Installed Bryant 70K BTU 80% efficiency gas furnace (model 800SB36070M17), Bryant 2.5 ton 15 SEER2 air conditioning unit (model CVAVA3017XMA), and Bryant evaporator coil (model GA5SAN53000W) with digital thermostat. Installation included outdoor unit pad, electrical whip kit, electrical disconnect box, 10 feet of insulated refrigerant line set, refrigerant line filter drier, transition from evaporator coil to existing ductwork, and SS2 coil drain safety water sensor. Obtained applicable permits, tested system operation, and enrolled equipment in annual maintenance care plan with semi-annual inspections. System covered by 1-year labor warranty, 10-year parts warranty, and 20-year heat exchanger warranty.
Lexington, KY 40502
Responded to a main drain cleanout service call for a clogged jetted bathtub in the master bathroom that was experiencing backfilling issues. Successfully cleared the obstruction from the tub drain, restoring proper drainage function to the fixture.
Responded to a main drain cleanout service call for a clogged jetted bathtub in the master bathroom that was experiencing backfilling issues. Successfully cleared the obstruction from the tub drain, restoring proper drainage function to the fixture.
Alec L.
Alec L. Checked in
Responded to a main drain cleanout service call for a clogged jetted bathtub in the master bathroom that was experiencing backfilling issues. Successfully cleared the obstruction from the tub drain, restoring proper drainage function to the fixture.
Lexington, KY 40514
Completed comprehensive 65-point plumbing inspection in response to customer report of continuous running water. Conducted thorough examination of all accessible plumbing fixtures and components throughout the property. Inspected toilet assembly, including fill valve, flapper, flush valve, and tank components for signs of leakage or malfunction that could cause continuous water flow. Evaluated water supply lines, shut-off valves, and connections for proper operation and potential leak sources. Examined basement utility area where deteriorated concrete flooring and water staining on tiled walls indicated possible historical moisture intrusion issues. Documented all findings with photographic evidence for customer records and future reference.
Completed comprehensive 65-point plumbing inspection in response to customer report of continuous running water. Conducted thorough examination of all accessible plumbing fixtures and components throughout the property. Inspected toilet assembly, including fill valve, flapper, flush valve, and tank components for signs of leakage or malfunction that could cause continuous water flow. Evaluated water supply lines, shut-off valves, and connections for proper operation and potential leak sources. Examined basement utility area where deteriorated concrete flooring and water staining on tiled walls indicated possible historical moisture intrusion issues. Documented all findings with photographic evidence for customer records and future reference.
Nic Q.
Nic Q. Checked in
Completed comprehensive 65-point plumbing inspection in response to customer report of continuous running water. Conducted thorough examination of all accessible plumbing fixtures and components throughout the property. Inspected toilet assembly, including fill valve, flapper, flush valve, and tank components for signs of leakage or malfunction that could cause continuous water flow. Evaluated water supply lines, shut-off valves, and connections for proper operation and potential leak sources. Examined basement utility area where deteriorated concrete flooring and water staining on tiled walls indicated possible historical moisture intrusion issues. Documented all findings with photographic evidence for customer records and future reference.
Lexington, KY 40515
Lexington, KY - Responded to commercial no cooling call on 26-year-old electric AC system. Upon arrival, found evaporator coil completely frozen, preventing proper system operation. Advised customer that unit must undergo complete thaw cycle before accurate diagnostic testing can be performed to identify root cause of freezing condition. Inspected air filter condition in crawl space location and documented system components for follow-up service.
Braden B.
Braden B. Checked in
Responded to commercial no cooling call on 26-year-old electric AC system. Upon arrival, found evaporator coil completely frozen, preventing proper system operation. Advised customer that unit must undergo complete thaw cycle before accurate diagnostic testing can be performed to identify root cause of freezing condition. Inspected air filter condition in crawl space location and documented system components for follow-up service.
Lexington, KY 40511
Completed scheduled AC tune-up on a four-year-old Daikin cooling system with no reported issues or symptoms. Performed comprehensive preventive maintenance inspection, verified system operation, and supplied a 20x25x4 filter per customer request. Documented system condition with photos showing proper installation of furnace unit, ductwork, PVC condensate piping, and conducted diagnostic measurements to ensure optimal performance.
Completed scheduled AC tune-up on a four-year-old Daikin cooling system with no reported issues or symptoms. Performed comprehensive preventive maintenance inspection, verified system operation, and supplied a 20x25x4 filter per customer request. Documented system condition with photos showing proper installation of furnace unit, ductwork, PVC condensate piping, and conducted diagnostic measurements to ensure optimal performance.
Jalen S.
Jalen S. Checked in
Completed scheduled AC tune-up on a four-year-old Daikin cooling system with no reported issues or symptoms. Performed comprehensive preventive maintenance inspection, verified system operation, and supplied a 20x25x4 filter per customer request. Documented system condition with photos showing proper installation of furnace unit, ductwork, PVC condensate piping, and conducted diagnostic measurements to ensure optimal performance.
Lexington, KY 40502
Completed residential HVAC system installation featuring a Lennox ML14KC1-042-230 3.5-ton air conditioning unit rated up to 17 SEER2 and matching Lennox CK40HT-42B71 3.5-ton evaporator coil. Removed and properly disposed of existing equipment, then installed new outdoor condensing unit on concrete pad with electrical disconnect box, whip kit, and DiversiTech weather-resistant enclosure. Installed evaporator coil with transition to existing ductwork, refrigerant line insulation, and refrigerant line filter drier. Added SS2 coil drain safety water sensor for overflow protection. Installed new digital thermostat and completed all electrical connections per code requirements. Secured all applicable permits, tested system operation, and verified proper refrigerant charge and airflow. System is fully operational with 10-year parts warranty and 1-year labor warranty, and client enrolled in annual maintenance plan including two semi-annual inspections.
Completed residential HVAC system installation featuring a Lennox ML14KC1-042-230 3.5-ton air conditioning unit rated up to 17 SEER2 and matching Lennox CK40HT-42B71 3.5-ton evaporator coil. Removed and properly disposed of existing equipment, then installed new outdoor condensing unit on concrete pad with electrical disconnect box, whip kit, and DiversiTech weather-resistant enclosure. Installed evaporator coil with transition to existing ductwork, refrigerant line insulation, and refrigerant line filter drier. Added SS2 coil drain safety water sensor for overflow protection. Installed new digital thermostat and completed all electrical connections per code requirements. Secured all applicable permits, tested system operation, and verified proper refrigerant charge and airflow. System is fully operational with 10-year parts warranty and 1-year labor warranty, and client enrolled in annual maintenance plan including two semi-annual inspections.
Gideon J.
Gideon J. Checked in
Completed residential HVAC system installation featuring a Lennox ML14KC1-042-230 3.5-ton air conditioning unit rated up to 17 SEER2 and matching Lennox CK40HT-42B71 3.5-ton evaporator coil. Removed and properly disposed of existing equipment, then installed new outdoor condensing unit on concrete pad with electrical disconnect box, whip kit, and DiversiTech weather-resistant enclosure. Installed evaporator coil with transition to existing ductwork, refrigerant line insulation, and refrigerant line filter drier. Added SS2 coil drain safety water sensor for overflow protection. Installed new digital thermostat and completed all electrical connections per code requirements. Secured all applicable permits, tested system operation, and verified proper refrigerant charge and airflow. System is fully operational with 10-year parts warranty and 1-year labor warranty, and client enrolled in annual maintenance plan including two semi-annual inspections.
Lexington, KY 40505
Completed warranty replacement of both compressors on a 20-ton commercial package unit with two-person crew. Prior to installation, evacuated nitrogen from system that had been introduced during previous leak detection procedures. Installed replacement compressor units, verified proper electrical connections and specifications, and charged system with appropriate refrigerant per manufacturer guidelines. Confirmed operational status of both compressors and overall unit performance upon completion.
Completed warranty replacement of both compressors on a 20-ton commercial package unit with two-person crew. Prior to installation, evacuated nitrogen from system that had been introduced during previous leak detection procedures. Installed replacement compressor units, verified proper electrical connections and specifications, and charged system with appropriate refrigerant per manufacturer guidelines. Confirmed operational status of both compressors and overall unit performance upon completion.
Braden B.
Braden B. Checked in
Completed warranty replacement of both compressors on a 20-ton commercial package unit with two-person crew. Prior to installation, evacuated nitrogen from system that had been introduced during previous leak detection procedures. Installed replacement compressor units, verified proper electrical connections and specifications, and charged system with appropriate refrigerant per manufacturer guidelines. Confirmed operational status of both compressors and overall unit performance upon completion.
Lexington, KY 40511
Lexington, KY - Responded to no cooling complaint on 7-year-old electric air conditioning system. Upon arrival, found thermostat set to 74°F with indoor temperature reading 78°F. Indoor blower motor operational, no visible ice formation on evaporator coil, and electrical breakers in proper position. Customer reported unit not cooling properly after returning from extended absence. Filter had been replaced 2 days prior to service call. Performed diagnostic evaluation to identify cause of insufficient cooling capacity.
Andrew W.
Andrew W. Checked in
Responded to no cooling complaint on 7-year-old electric air conditioning system. Upon arrival, found thermostat set to 74°F with indoor temperature reading 78°F. Indoor blower motor operational, no visible ice formation on evaporator coil, and electrical breakers in proper position. Customer reported unit not cooling properly after returning from extended absence. Filter had been replaced 2 days prior to service call. Performed diagnostic evaluation to identify cause of insufficient cooling capacity.
Lexington, KY 40513
Responded to service call for newly installed HVAC system not cooling adequately, with indoor temperature reading 79°F. Upon arrival, connected refrigerant manifold gauges and verified system pressures and temperatures, which indicated low refrigerant charge. Added 5.00 lbs of refrigerant to system per manufacturer specifications using calibrated digital scale. System now operating within normal parameters and cooling properly.
Responded to service call for newly installed HVAC system not cooling adequately, with indoor temperature reading 79°F. Upon arrival, connected refrigerant manifold gauges and verified system pressures and temperatures, which indicated low refrigerant charge. Added 5.00 lbs of refrigerant to system per manufacturer specifications using calibrated digital scale. System now operating within normal parameters and cooling properly.
Travis M.
Travis M. Checked in
Responded to service call for newly installed HVAC system not cooling adequately, with indoor temperature reading 79°F. Upon arrival, connected refrigerant manifold gauges and verified system pressures and temperatures, which indicated low refrigerant charge. Added 5.00 lbs of refrigerant to system per manufacturer specifications using calibrated digital scale. System now operating within normal parameters and cooling properly.
Lexington, KY 40507
Lexington, KY - Responded to no cooling call on electric air conditioning system with outdoor unit not running. Upon arrival, thermostat was set to 72 degrees with indoor temperature reading 76 degrees. Performed diagnostic inspection of both indoor air handler and outdoor condensing unit. Indoor unit inspection revealed significant accumulation of dust and debris throughout the cabinet and on blower assembly, indicating extended period without maintenance. Blower wheel showed heavy dust buildup that could restrict airflow and reduce system efficiency. Access panel area showed signs of moisture exposure with visible staining. Checked electrical connections, capacitors, and contactor on outdoor unit. Identified failed run capacitor as primary cause of condenser unit failure. Replaced defective capacitor and verified proper voltage and amperage readings. Tested system operation and confirmed outdoor unit running properly with adequate cooling cycle initiated. Recommended thorough cleaning of indoor blow
Matt B.
Matt B. Checked in
Responded to no cooling call on electric air conditioning system with outdoor unit not running. Upon arrival, thermostat was set to 72 degrees with indoor temperature reading 76 degrees. Performed diagnostic inspection of both indoor air handler and outdoor condensing unit. Indoor unit inspection revealed significant accumulation of dust and debris throughout the cabinet and on blower assembly, indicating extended period without maintenance. Blower wheel showed heavy dust buildup that could restrict airflow and reduce system efficiency. Access panel area showed signs of moisture exposure with visible staining. Checked electrical connections, capacitors, and contactor on outdoor unit. Identified failed run capacitor as primary cause of condenser unit failure. Replaced defective capacitor and verified proper voltage and amperage readings. Tested system operation and confirmed outdoor unit running properly with adequate cooling cycle initiated. Recommended thorough cleaning of indoor blow
Lexington, KY 40505
Responded to no cooling complaint on 7-year-old mini split system blowing warm air. Performed diagnostic evaluation of both indoor wall-mounted evaporator unit and outdoor condenser unit. Inspected refrigerant line connections, electrical components, and overall system operation. Documented equipment condition with outdoor unit showing normal wear and indoor unit properly mounted in stairwell area. Completed troubleshooting procedures to identify root cause of warm air discharge issue.
Responded to no cooling complaint on 7-year-old mini split system blowing warm air. Performed diagnostic evaluation of both indoor wall-mounted evaporator unit and outdoor condenser unit. Inspected refrigerant line connections, electrical components, and overall system operation. Documented equipment condition with outdoor unit showing normal wear and indoor unit properly mounted in stairwell area. Completed troubleshooting procedures to identify root cause of warm air discharge issue.
Andrew W.
Andrew W. Checked in
Responded to no cooling complaint on 7-year-old mini split system blowing warm air. Performed diagnostic evaluation of both indoor wall-mounted evaporator unit and outdoor condenser unit. Inspected refrigerant line connections, electrical components, and overall system operation. Documented equipment condition with outdoor unit showing normal wear and indoor unit properly mounted in stairwell area. Completed troubleshooting procedures to identify root cause of warm air discharge issue.
Lexington, KY 40509
Lexington, KY - Removed and capped the existing sump pump discharge line inside the structure. Rerouted new discharge piping through the foundation wall to the exterior, terminating with a flush-mounted pop-up emitter in the lawn area. All connections were secured and tested to ensure proper drainage function.
Logan C.
Logan C. Checked in
Removed and capped the existing sump pump discharge line inside the structure. Rerouted new discharge piping through the foundation wall to the exterior, terminating with a flush-mounted pop-up emitter in the lawn area. All connections were secured and tested to ensure proper drainage function.
Lexington, KY 40505
Responded to no cooling call on downstairs heat pump system. Upon inspection of the air handler unit located in attic space, discovered failed transformer with visible burn damage and melted housing. Transformer showed clear signs of thermal failure and was preventing the indoor unit from receiving power. Removed damaged transformer and replaced with new unit, reconnected all control wiring per manufacturer specifications, and restored power to system. Verified proper operation of air handler blower motor and confirmed unit now responds to thermostat calls. System operational at time of departure.
Responded to no cooling call on downstairs heat pump system. Upon inspection of the air handler unit located in attic space, discovered failed transformer with visible burn damage and melted housing. Transformer showed clear signs of thermal failure and was preventing the indoor unit from receiving power. Removed damaged transformer and replaced with new unit, reconnected all control wiring per manufacturer specifications, and restored power to system. Verified proper operation of air handler blower motor and confirmed unit now responds to thermostat calls. System operational at time of departure.
Matt T.
Matt T. Checked in
Responded to no cooling call on downstairs heat pump system. Upon inspection of the air handler unit located in attic space, discovered failed transformer with visible burn damage and melted housing. Transformer showed clear signs of thermal failure and was preventing the indoor unit from receiving power. Removed damaged transformer and replaced with new unit, reconnected all control wiring per manufacturer specifications, and restored power to system. Verified proper operation of air handler blower motor and confirmed unit now responds to thermostat calls. System operational at time of departure.
Lexington, KY 40509
Replaced failed 15 MFD single run capacitor and 45/5 MFD dual capacitor to restore proper system operation. Performed leak detection using electronic detector to locate refrigerant leak in outdoor unit. Reconnected disconnected drain safety float switch and tested for proper operation to ensure condensate overflow protection is functioning correctly.
Replaced failed 15 MFD single run capacitor and 45/5 MFD dual capacitor to restore proper system operation. Performed leak detection using electronic detector to locate refrigerant leak in outdoor unit. Reconnected disconnected drain safety float switch and tested for proper operation to ensure condensate overflow protection is functioning correctly.
Andrew W.
Andrew W. Checked in
Replaced failed 15 MFD single run capacitor and 45/5 MFD dual capacitor to restore proper system operation. Performed leak detection using electronic detector to locate refrigerant leak in outdoor unit. Reconnected disconnected drain safety float switch and tested for proper operation to ensure condensate overflow protection is functioning correctly.
Lexington, KY 40502
Lexington, KY - Performed comprehensive plumbing inspection on Lochinvar residential water heater installed in 2019. Upon evaluation, determined the unit was in suitable condition to perform a complete tank flush, successfully draining sediment buildup and refilling the system to restore optimal performance and extend equipment lifespan.
Caddo D.
Caddo D. Checked in
Performed comprehensive plumbing inspection on Lochinvar residential water heater installed in 2019. Upon evaluation, determined the unit was in suitable condition to perform a complete tank flush, successfully draining sediment buildup and refilling the system to restore optimal performance and extend equipment lifespan.
Lexington, KY 40509
Responded to service call for 10-year-old Generac generator that failed to activate during recent power outage. Performed diagnostic inspection of generator system, transfer switch, and associated electrical panels in basement utility room. Documented existing electrical infrastructure including Generac automatic transfer switch, multiple breaker panels, and wiring configurations for service records.
Responded to service call for 10-year-old Generac generator that failed to activate during recent power outage. Performed diagnostic inspection of generator system, transfer switch, and associated electrical panels in basement utility room. Documented existing electrical infrastructure including Generac automatic transfer switch, multiple breaker panels, and wiring configurations for service records.
Trent E.
Trent E. Checked in
Responded to service call for 10-year-old Generac generator that failed to activate during recent power outage. Performed diagnostic inspection of generator system, transfer switch, and associated electrical panels in basement utility room. Documented existing electrical infrastructure including Generac automatic transfer switch, multiple breaker panels, and wiring configurations for service records.
Lexington, KY 40502
Lexington, KY - Completed AC tune-up on 2-year-old system per customer request for filter change. Upon inspection, discovered significant dust accumulation throughout air handler compartment and ductwork, along with deteriorated insulation material showing fraying and separation from backing. Changed filters, documented interior conditions with photos, and noted heavy debris buildup requiring attention to maintain system efficiency and air quality.
Matt B.
Matt B. Checked in
Completed AC tune-up on 2-year-old system per customer request for filter change. Upon inspection, discovered significant dust accumulation throughout air handler compartment and ductwork, along with deteriorated insulation material showing fraying and separation from backing. Changed filters, documented interior conditions with photos, and noted heavy debris buildup requiring attention to maintain system efficiency and air quality.
Lexington, KY 40504
Conducted site assessment for water heater relocation in residential utility space. Current A.O. Smith water heater is positioned in alcove blocking access to washer and dryer hookups. Evaluated existing installation including gas connections, water supply lines, venting system, and electrical requirements. Documented current placement with measurements and photographic evidence. Prepared estimate for relocating unit to alternative position that will provide unobstructed access to laundry connections while maintaining code compliance for clearances, venting, and utility connections.
Conducted site assessment for water heater relocation in residential utility space. Current A.O. Smith water heater is positioned in alcove blocking access to washer and dryer hookups. Evaluated existing installation including gas connections, water supply lines, venting system, and electrical requirements. Documented current placement with measurements and photographic evidence. Prepared estimate for relocating unit to alternative position that will provide unobstructed access to laundry connections while maintaining code compliance for clearances, venting, and utility connections.
Shaun H.
Shaun H. Checked in
Conducted site assessment for water heater relocation in residential utility space. Current A.O. Smith water heater is positioned in alcove blocking access to washer and dryer hookups. Evaluated existing installation including gas connections, water supply lines, venting system, and electrical requirements. Documented current placement with measurements and photographic evidence. Prepared estimate for relocating unit to alternative position that will provide unobstructed access to laundry connections while maintaining code compliance for clearances, venting, and utility connections.
Lexington, KY 40511

Why GreenBox?

We Pride Ourselves On Friendly, Honest Customer Service

Craftsmanship Guaranteed

We will do what it takes to ensure your satisfaction with the quality of your installation.

Emergency Service

Our live support team is available around the clock for emergency call intake and priority dispatch for your heating and cooling needs.

Upfront Pricing

You will know the cost of your service before we start any work.

365-Day Guarantee

If a system installed by us doesn't meet your needs after one year, we will refund you 100%.

Same-Day Installation

We can install your new heating or cooling system in as little as one day.

Free In-Home Estimate

We want your service to be easy and convenient, so we offer free estimates.

Craftsmanship Guaranteed

We will do what it takes to ensure your satisfaction with the quality of your installation.

Emergency Service

Our live support team is available around the clock for emergency call intake and priority dispatch for your heating and cooling needs.

Upfront Pricing

You will know the cost of your service before we start any work.

365-Day Guarantee

If a system installed by us doesn't meet your needs after one year, we will refund you 100%.

Same-Day Installation

We can install your new heating or cooling system in as little as one day.

Free In-Home Estimate

We want your service to be easy and convenient, so we offer free estimates.

Review Image

What Our Clients Are Saying

I am very impressed by the customer service I received at GreenBox. The person answering my call was kind and had a sense of urgency to address my need. I appreciated the text correspondence and the ability to coordinate timing of the technician’s visit. It was…

Amy W.

Amy W.

I was so impressed with with David. He was so knowledgeable and helped me make the best decision for me. The installation was done quickly and professionally. I am so very happy that I went with GreenBox. I would highly recommend you business to family and…

Linda M.

Linda M.

Fantastic service helped me within a hour I can’t say enough good things about Matt and GreenBox thanks again!!!!!!!

Joey T.

Joey T.

Love GreenBox!! Always professional. Very knowledgeable. Hard working, fair, courteous, clean and just good!

Kelly S.

Kelly S.

Great customer service and value. The technician Robert Caudill called ahead of time as requested and did a great job. Would definitely recommend GreenBox to anyone needing service or sales!

Chad M.

Chad M.