Heating, Cooling, Plumbing & Electrical Services in Lexington, KY
Emergency Service
Unforeseen HVAC or plumbing issues can disrupt your comfort at times. Our Emergency Service guarantees swift attention. Day or night, reach out for immediate resolution, ensuring your home or business stays comfortable and functional, providing you with peace of mind around the clock. Give us a call at (859) 203-5124.
Emergency Service
Unforeseen HVAC or plumbing issues can disrupt your comfort at times. Our Emergency Service guarantees swift attention. Day or night, reach out for immediate resolution, ensuring your home or business stays comfortable and functional, providing you with peace of mind around the clock. Give us a call at (859) 203-5124.

Top-Rated Heating, Cooling in Lexington, KY

Plumbing & Electrical Services

 

Lexington Service Overview

  • Local Priority: We provide dedicated HVAC, plumbing, electrical, and indoor air quality support across the entire Lexington community.

  • Certified Expertise: Our technicians are highly trained to handle the unique infrastructure, historic home preservation needs, and seasonal climate swings of Fayette County homes.

  • Efficiency Focus: We specialize in optimizing your heating, cooling, and plumbing systems to ensure long-term, year-round comfort and reduced utility costs.

 

From the historic homes lining Richmond Road and the tree-lined streets of Chevy Chase to the growing neighborhoods around Hamburg, Masterson Station, and Citation Boulevard, Lexington homeowners rely on their home’s essential systems every day. GreenBox Heating & Air provides expert heating, cooling, plumbing, electrical, and indoor air quality services throughout Lexington, KY. 

Our team understands the unique needs of Central Kentucky homes, whether we’re working on a century-old property near Ashland Park, a ranch home in Gardenside, or a newer build off Man o’ War Boulevard.

Call (859) 203-5124 today to schedule service in Lexington.

Serving Lexington Homeowners Every Day

Lexington continues to grow, but many neighborhoods still feature homes built decades ago with aging plumbing, electrical, and HVAC systems. GreenBox Heating & Air works throughout Fayette County every day, helping homeowners near The Arboretum, Beaumont Centre, Tates Creek, and Downtown Lexington keep their homes safe, comfortable, and efficient.

Whether you’re dealing with an unexpected breakdown during a Kentucky cold snap or planning upgrades before summer arrives, our technicians bring local experience and dependable solutions to every job.

 

“I had a project in mind and it hinged on a natural gas line evaluation. Green Box promptly responded and Caddo Downs came yesterday to assess the situation. Caddo provided excellent feedback. GreenBox’s expertise and staff always lead me down the right path with a positive outcome. GreenBox is my go-to for plumbing, heating, air and electrical services.”

— Bridget S.

Plumbing Services in Lexington, KY

Plumbing issues can vary dramatically across Lexington. In neighborhoods like Kenwick, Bell Court, and Ashland Park, older water and drain lines often require repairs or replacement. In newer communities near Hamburg and Hartland, homeowners frequently call us for water heater upgrades, fixture installations, and water quality improvements.

Our Lexington plumbing team can help with:

  • Diagnosing hidden leaks before they cause damage to walls, flooring, or foundations
  • Clearing stubborn drain and sewer line blockages that disrupt daily routines
  • Repairing or replacing water heaters to ensure reliable hot water year-round
  • Upgrading aging pipes in older Lexington homes with modern plumbing materials
  • Installing gas lines for appliances, fireplaces, and outdoor living spaces
  • Improving water quality with filtration and treatment solutions designed for local households
  • Responding quickly to emergency plumbing situations throughout Fayette County

Whether you’re renovating a home near Woodland Park or dealing with a plumbing emergency off Nicholasville Road, GreenBox delivers solutions built to last.

Get Reliable Lexington Plumber Today by calling (859) 203-5124 or Schedule your Service Online!

Heating Services in Lexington, KY

Lexington winters can bring freezing temperatures, ice, and sudden weather swings that put heating systems to the test. Homes throughout neighborhoods like Chevy Chase and Fairway often rely on older furnaces or boiler systems, while many newer homes near Brannon Crossing and Hamburg utilize high-efficiency heat pumps.

Our heating services are designed to help Lexington homeowners:

  • Restore heat quickly when furnaces, boilers, or heat pumps stop working
  • Improve energy efficiency and lower winter utility costs
  • Replace aging heating equipment before costly breakdowns occur
  • Maintain reliable comfort through seasonal tune-ups and inspections
  • Upgrade older systems with modern, high-performance heating technology
  • Address uneven temperatures and comfort issues throughout the home
  • Prepare heating equipment for Kentucky’s unpredictable winter weather

From homes near Southland Drive to properties along Versailles Road, GreenBox helps keep Lexington families warm and comfortable all season long.

Restore Warmth Fast: Schedule Lexington Furnace or Boiler Repair!

 

“Jayden C. did a great job with our HVAC maintenance visit. We had questions about our thermostat and he was able to offer options for us to upgrade. He was on time and worked quickly. We’re always pleased with GreenBox Heating & Air!”

— Leo L.

Solving Lexington Home Issues 

Problem: An aging furnace or historic boiler is struggling to keep up with unpredictable Kentucky cold snaps, leading to uneven home temperatures and soaring winter utility bills.

Solution: We perform precision tune-ups, urgent system fixes, or high-efficiency furnace and heat pump installations to ensure your living spaces stay warm while keeping your monthly costs manageable.


Problem: Outdated electrical panels and aging wiring in older neighborhoods like Chevy Chase or Bell Court cannot safely support modern appliances, EV chargers, or smart home electronics.

Solution: Our licensed electricians provide comprehensive panel upgrades and code-compliant rewiring to safely meet the power demands of your growing household.


Problem: Hard water buildup, hidden pipe leaks, or slow drains are disrupting daily routines and threatening the structural safety of older Central Kentucky properties.

Solution: We deliver fast drain clearing, hidden leak diagnostics, and modern pipe replacements with premium materials built to last.

Air Conditioning Services in Lexington, KY

Anyone who has spent a summer in Lexington knows how quickly heat and humidity can make indoor spaces uncomfortable. When temperatures climb and humidity settles over the Bluegrass region, homeowners need cooling systems they can depend on.

Our cooling specialists help homeowners:

Whether you’re near Hamburg Pavilion, UK’s campus, or Veterans Park, GreenBox provides cooling solutions tailored to your home’s needs.

Book Professional AC Service Today by calling (859) 203-5124 

Electrical Services in Lexington, KY

Lexington’s housing market includes everything from historic homes with outdated wiring to newly constructed properties equipped with modern technology. As electrical demands continue to increase, many homeowners find their existing systems need upgrades to keep pace.

Electrical Installation in Lexington KY

Our electricians help Lexington homeowners:

Whether you’re updating a historic property near Downtown Lexington or adding new technology to a home in Hartland, our licensed electricians provide safe, code-compliant solutions.

Schedule Your Code-Compliant Electrical Inspection Today!

Lexington ZIP Codes We Serve

GreenBox Heating & Air proudly serves homeowners throughout Lexington and surrounding Fayette County communities.

We provide service throughout:

  • 40502
  • 40503
  • 40504
  • 40508
  • 40509
  • 40511
  • 40513
  • 40514
  • 40515
  • 40517

Whether you’re located near Downtown Lexington, Hamburg, Beaumont, Tates Creek, Masterson Station, Gardenside, or Chevy Chase, our team is ready to help!

 

“Outstanding support as always. We have counted on this company for years and truly grateful for their excellent work. All team members are so smart, considerate and dependable.”

— Lauren P.

Why Lexington Chooses GreenBox

  • Lexington homeowners expect exceptional service and local accountability from the companies they hire. Here is why your neighbors trust GreenBox Heating & Air:

Experienced Technicians: Skilled local professionals who understand the plumbing, HVAC, and electrical quirks of everything from historic properties near Ashland Park to new builds off Man o’ War Boulevard.

Clear, Honest Recommendations: No high-pressure sales or hidden surprises. We provide straightforward diagnostics and honest options tailored directly to your home’s layout and budget.

All-in-One Convenience: Complete expertise across plumbing, heating, cooling, electrical, and indoor air quality lines so you only have to make one reliable call to keep your home running smoothly.

Community Commitment: We work throughout Fayette County every day, bringing professional workmanship and a steadfast commitment to long-term home comfort and safety.

Schedule Service in Lexington, KY

Whether you need emergency plumbing repairs near Tates Creek, a furnace replacement in Chevy Chase, AC service in Hamburg, or electrical upgrades in Beaumont, GreenBox Heating & Air is ready to help. Our team proudly serves homeowners throughout Lexington with expert workmanship, responsive service, and solutions designed for Kentucky homes. From routine maintenance and system tune-ups to complex repairs and full equipment replacements, indoor air quality solutions– we provide the dependable support local homeowners need to keep their homes comfortable, safe, and efficient throughout every season.

 

 FAQs for Lexington Homeowners

In historic Lexington areas like Kenwick, Bell Court, and Ashland Park, plumbing emergencies are frequently caused by aging water lines, corroded sewer pipes, and stubborn root intrusions. Over time, these outdated materials weaken, leading to sudden hidden leaks, structural drain blockages, and low water pressure that require immediate professional diagnostics or pipe replacement.

Uneven temperatures are common in multi-story Central Kentucky homes, especially those with older furnaces or boilers. This issue is typically caused by restricted airflow, aging equipment struggling to maintain pressure, or a lack of modern zone-control systems. Upgrading to a high-efficiency heat pump or scheduling a seasonal heating tune-up can optimize airflow and lower winter utility costs.

Many historic homes in neighborhoods like Bell Court and Chevy Chase were built decades ago with electrical systems that cannot handle modern energy demands. As households add high-powered electronics, modern appliances, and EV chargers, these aging panels frequently overload, causing tripped breakers, flickering lights, and serious safety hazards. Upgrading to a modern electrical panel ensures code-compliant safety and provides stable, reliable power throughout your property.

Page Updated on June 29, 2026

Recent Jobs and Reviews in Lexington, KY

Lexington, KY at a glance

Greenbox Home Services has completed 20 jobs in Lexington, KY in August 2026.

The most recent job was on August 17, 2026.

Greenbox Home Services has completed 2,923 jobs in Lexington, KY in the last 12 months.

Job Locations and Reviews

Completed preventative maintenance tune-up on air conditioning system as part of Club Green PSA agreement. Accessed attic-mounted HVAC unit via pull-down ladder, performed standard system inspection, and replaced 20x20x1 air filter at return air vent. All system components operating within normal parameters.
Completed preventative maintenance tune-up on air conditioning system as part of Club Green PSA agreement. Accessed attic-mounted HVAC unit via pull-down ladder, performed standard system inspection, and replaced 20x20x1 air filter at return air vent. All system components operating within normal parameters.
Andrew W.
Andrew W. Checked in
Completed preventative maintenance tune-up on air conditioning system as part of Club Green PSA agreement. Accessed attic-mounted HVAC unit via pull-down ladder, performed standard system inspection, and replaced 20x20x1 air filter at return air vent. All system components operating within normal parameters.
Lexington, KY 40503
Responded to service call for kitchen sink with garbage disposal backing up. Performed complimentary whole home plumbing inspection as requested. Inspected double-basin kitchen sink with garbage disposal unit installed in left basin. Examined disposal operation, drain assembly, and P-trap configuration. Assessed water supply connections and drain lines behind adjacent appliances to verify proper venting and drainage flow. System evaluated for blockages, improper installation, or mechanical failure of disposal unit.
Responded to service call for kitchen sink with garbage disposal backing up. Performed complimentary whole home plumbing inspection as requested. Inspected double-basin kitchen sink with garbage disposal unit installed in left basin. Examined disposal operation, drain assembly, and P-trap configuration. Assessed water supply connections and drain lines behind adjacent appliances to verify proper venting and drainage flow. System evaluated for blockages, improper installation, or mechanical failure of disposal unit.
Nic Q.
Nic Q. Checked in
Responded to service call for kitchen sink with garbage disposal backing up. Performed complimentary whole home plumbing inspection as requested. Inspected double-basin kitchen sink with garbage disposal unit installed in left basin. Examined disposal operation, drain assembly, and P-trap configuration. Assessed water supply connections and drain lines behind adjacent appliances to verify proper venting and drainage flow. System evaluated for blockages, improper installation, or mechanical failure of disposal unit.
Lexington, KY 40509
# HVAC Service Report - No Cool Condition

Responded to service call for one-year-old air conditioning system with insufficient cooling capacity. Unit was providing some cooling but failing to maintain desired temperature setpoints throughout the property.

Upon arrival, performed visual inspection of outdoor condensing unit and indoor air handler components. Proceeded to attic space to examine air distribution system and indoor equipment. During inspection, discovered compromised ductwork insulation at critical connection points near the air handler unit. Black exterior insulation jacket was torn and separated from duct surfaces, with underlying reflective vapor barrier material exposed, crumpled, and improperly sealed.

The deteriorated insulation condition was causing significant thermal loss at the supply plenum connection, allowing conditioned air to lose temperature before reaching living spaces. This explained the reduced cooling performance despite the system being relatively n
# HVAC Service Report - No Cool Condition

Responded to service call for one-year-old air conditioning system with insufficient cooling capacity. Unit was providing some cooling but failing to maintain desired temperature setpoints throughout the property.

Upon arrival, performed visual inspection of outdoor condensing unit and indoor air handler components. Proceeded to attic space to examine air distribution system and indoor equipment. During inspection, discovered compromised ductwork insulation at critical connection points near the air handler unit. Black exterior insulation jacket was torn and separated from duct surfaces, with underlying reflective vapor barrier material exposed, crumpled, and improperly sealed.

The deteriorated insulation condition was causing significant thermal loss at the supply plenum connection, allowing conditioned air to lose temperature before reaching living spaces. This explained the reduced cooling performance despite the system being relatively n
Matt B.
Matt B. Checked in
# HVAC Service Report - No Cool Condition Responded to service call for one-year-old air conditioning system with insufficient cooling capacity. Unit was providing some cooling but failing to maintain desired temperature setpoints throughout the property. Upon arrival, performed visual inspection of outdoor condensing unit and indoor air handler components. Proceeded to attic space to examine air distribution system and indoor equipment. During inspection, discovered compromised ductwork insulation at critical connection points near the air handler unit. Black exterior insulation jacket was torn and separated from duct surfaces, with underlying reflective vapor barrier material exposed, crumpled, and improperly sealed. The deteriorated insulation condition was causing significant thermal loss at the supply plenum connection, allowing conditioned air to lose temperature before reaching living spaces. This explained the reduced cooling performance despite the system being relatively n
Lexington, KY 40502
Completed comprehensive Club Trio maintenance service on multi-zone HVAC system consisting of 2 indoor air handlers and 3 outdoor condensing units located in basement and attic. Performed thorough inspection and tune-up procedures on heat pump/air handler, gas furnace/air conditioner, and additional air conditioning system per recurring service agreement.

Conducted detailed assessment of all equipment, including visual inspection of evaporator coils, blower assemblies, drain pans, and condensate systems. Documentation revealed significant dust and debris accumulation on evaporator coil fins and heavy biological growth with water staining in condensate drain pan, indicating extended service interval and moisture exposure. Blower wheel showed operational condition with moderate dust buildup on housing components.

Performed standard preventive maintenance protocols including system operational checks, electrical connection inspections, refrigerant level assessments, and airflow evaluati
Completed comprehensive Club Trio maintenance service on multi-zone HVAC system consisting of 2 indoor air handlers and 3 outdoor condensing units located in basement and attic. Performed thorough inspection and tune-up procedures on heat pump/air handler, gas furnace/air conditioner, and additional air conditioning system per recurring service agreement.

Conducted detailed assessment of all equipment, including visual inspection of evaporator coils, blower assemblies, drain pans, and condensate systems. Documentation revealed significant dust and debris accumulation on evaporator coil fins and heavy biological growth with water staining in condensate drain pan, indicating extended service interval and moisture exposure. Blower wheel showed operational condition with moderate dust buildup on housing components.

Performed standard preventive maintenance protocols including system operational checks, electrical connection inspections, refrigerant level assessments, and airflow evaluati
Andrew W.
Andrew W. Checked in
Completed comprehensive Club Trio maintenance service on multi-zone HVAC system consisting of 2 indoor air handlers and 3 outdoor condensing units located in basement and attic. Performed thorough inspection and tune-up procedures on heat pump/air handler, gas furnace/air conditioner, and additional air conditioning system per recurring service agreement. Conducted detailed assessment of all equipment, including visual inspection of evaporator coils, blower assemblies, drain pans, and condensate systems. Documentation revealed significant dust and debris accumulation on evaporator coil fins and heavy biological growth with water staining in condensate drain pan, indicating extended service interval and moisture exposure. Blower wheel showed operational condition with moderate dust buildup on housing components. Performed standard preventive maintenance protocols including system operational checks, electrical connection inspections, refrigerant level assessments, and airflow evaluati
Lexington, KY 40502
Completed full replacement of residential tanked water heater in utility closet installation. Removed existing unit and installed new white cylindrical water heater with proper clearances and code-compliant connections. Connected hot and cold water supply lines using copper piping with red-handled and blue-handled shut-off valves at unit top for isolation capability. Verified gas supply connection with yellow ball valve shut-off mechanism and black iron gas pipe with properly sealed threaded connections. Ensured all plumbing connections were secure and leak-free, with water heater properly positioned within confined closet space. Installation includes standard electrical connection via wall outlet and meets manufacturer specifications for residential water heating system operation.
Completed full replacement of residential tanked water heater in utility closet installation. Removed existing unit and installed new white cylindrical water heater with proper clearances and code-compliant connections. Connected hot and cold water supply lines using copper piping with red-handled and blue-handled shut-off valves at unit top for isolation capability. Verified gas supply connection with yellow ball valve shut-off mechanism and black iron gas pipe with properly sealed threaded connections. Ensured all plumbing connections were secure and leak-free, with water heater properly positioned within confined closet space. Installation includes standard electrical connection via wall outlet and meets manufacturer specifications for residential water heating system operation.
Shaun H.
Shaun H. Checked in
Completed full replacement of residential tanked water heater in utility closet installation. Removed existing unit and installed new white cylindrical water heater with proper clearances and code-compliant connections. Connected hot and cold water supply lines using copper piping with red-handled and blue-handled shut-off valves at unit top for isolation capability. Verified gas supply connection with yellow ball valve shut-off mechanism and black iron gas pipe with properly sealed threaded connections. Ensured all plumbing connections were secure and leak-free, with water heater properly positioned within confined closet space. Installation includes standard electrical connection via wall outlet and meets manufacturer specifications for residential water heating system operation.
Lexington, KY 40511
Responded to commercial property no-cooling complaint with interior temperature at 87°F. Inspected 9-year-old Goodman N4H448GBP100 condenser unit and found system operational with proper refrigerant charge and compressor function. Verified unit specifications, electrical connections, and heat exchanger components showed no visible defects or refrigerant leaks, with all safety labels and certifications intact.
Responded to commercial property no-cooling complaint with interior temperature at 87°F. Inspected 9-year-old Goodman N4H448GBP100 condenser unit and found system operational with proper refrigerant charge and compressor function. Verified unit specifications, electrical connections, and heat exchanger components showed no visible defects or refrigerant leaks, with all safety labels and certifications intact.
Carter B.
Carter B. Checked in
Responded to commercial property no-cooling complaint with interior temperature at 87°F. Inspected 9-year-old Goodman N4H448GBP100 condenser unit and found system operational with proper refrigerant charge and compressor function. Verified unit specifications, electrical connections, and heat exchanger components showed no visible defects or refrigerant leaks, with all safety labels and certifications intact.
Lexington, KY 40513
Responded to service call for water leak on 20-year-old electric HVAC system with indoor unit located inside front door. Upon inspection, discovered evaporator coil completely frozen with thick ice accumulation across all fins, indicating restricted airflow as primary cause of condensation leak. Assessed outdoor condenser unit showing signs of age and weathering but operational. Diagnosed frozen coil condition likely caused by combination of dirty/restricted evaporator coil, possible low refrigerant charge, and inadequate airflow from neglected filter maintenance. Documented extensive frost buildup on coil surfaces and overall system condition with photographic evidence. Advised that system requires coil cleaning, refrigerant charge verification, and regular filter maintenance to prevent recurrence of freezing and water leak issues.
Responded to service call for water leak on 20-year-old electric HVAC system with indoor unit located inside front door. Upon inspection, discovered evaporator coil completely frozen with thick ice accumulation across all fins, indicating restricted airflow as primary cause of condensation leak. Assessed outdoor condenser unit showing signs of age and weathering but operational. Diagnosed frozen coil condition likely caused by combination of dirty/restricted evaporator coil, possible low refrigerant charge, and inadequate airflow from neglected filter maintenance. Documented extensive frost buildup on coil surfaces and overall system condition with photographic evidence. Advised that system requires coil cleaning, refrigerant charge verification, and regular filter maintenance to prevent recurrence of freezing and water leak issues.
Braden B.
Braden B. Checked in
Responded to service call for water leak on 20-year-old electric HVAC system with indoor unit located inside front door. Upon inspection, discovered evaporator coil completely frozen with thick ice accumulation across all fins, indicating restricted airflow as primary cause of condensation leak. Assessed outdoor condenser unit showing signs of age and weathering but operational. Diagnosed frozen coil condition likely caused by combination of dirty/restricted evaporator coil, possible low refrigerant charge, and inadequate airflow from neglected filter maintenance. Documented extensive frost buildup on coil surfaces and overall system condition with photographic evidence. Advised that system requires coil cleaning, refrigerant charge verification, and regular filter maintenance to prevent recurrence of freezing and water leak issues.
Lexington, KY 40507
Responded to no cooling call with indoor temperature reaching 85°F. Upon inspection, found attic-mounted air handler operating with supply air temperature of 127.4°F, indicating complete loss of cooling capacity. Thermostat displayed 80°F actual temperature with setpoint of 70°F in cooling mode. Performed diagnostic evaluation of system components to identify cause of cooling failure and documented equipment conditions for repair recommendations.
Responded to no cooling call with indoor temperature reaching 85°F. Upon inspection, found attic-mounted air handler operating with supply air temperature of 127.4°F, indicating complete loss of cooling capacity. Thermostat displayed 80°F actual temperature with setpoint of 70°F in cooling mode. Performed diagnostic evaluation of system components to identify cause of cooling failure and documented equipment conditions for repair recommendations.
Braden B.
Braden B. Checked in
Responded to no cooling call with indoor temperature reaching 85°F. Upon inspection, found attic-mounted air handler operating with supply air temperature of 127.4°F, indicating complete loss of cooling capacity. Thermostat displayed 80°F actual temperature with setpoint of 70°F in cooling mode. Performed diagnostic evaluation of system components to identify cause of cooling failure and documented equipment conditions for repair recommendations.
Lexington, KY 40509
Responded to callback for HVAC system not turning on following previous water leak incident. Upon arrival, verified thermostat was set to 68°F with ambient temperature at 73°F. Confirmed no tripped breakers or frozen evaporator coil present. Inspected ductwork and system components in attic space, documenting condition of flexible duct connections and metal framework. Examined refrigerant sight glass showing amber-colored refrigerant level and condition. Performed diagnostic testing to determine if system failure was related to previous water intrusion event or separate issue requiring additional repair work.
Responded to callback for HVAC system not turning on following previous water leak incident. Upon arrival, verified thermostat was set to 68°F with ambient temperature at 73°F. Confirmed no tripped breakers or frozen evaporator coil present. Inspected ductwork and system components in attic space, documenting condition of flexible duct connections and metal framework. Examined refrigerant sight glass showing amber-colored refrigerant level and condition. Performed diagnostic testing to determine if system failure was related to previous water intrusion event or separate issue requiring additional repair work.
Cade R.
Cade R. Checked in
Responded to callback for HVAC system not turning on following previous water leak incident. Upon arrival, verified thermostat was set to 68°F with ambient temperature at 73°F. Confirmed no tripped breakers or frozen evaporator coil present. Inspected ductwork and system components in attic space, documenting condition of flexible duct connections and metal framework. Examined refrigerant sight glass showing amber-colored refrigerant level and condition. Performed diagnostic testing to determine if system failure was related to previous water intrusion event or separate issue requiring additional repair work.
Lexington, KY 40514
Responded to water leak complaint at indoor HVAC unit in sunroom that had been leaking for several days. Unit was off upon arrival. Performed diagnostic inspection and discovered condensate drain line issue with visible mineral deposits and buildup at drain connection point. Inspected attic space and ductwork, finding pink fiberglass insulation with signs of water damage and discoloration around affected area. Documented conditions with photographs showing deteriorated drain fitting with crusty residue accumulation and water-damaged insulation materials. Identified source of water intrusion coming from behind unit due to compromised condensate drainage system.
Responded to water leak complaint at indoor HVAC unit in sunroom that had been leaking for several days. Unit was off upon arrival. Performed diagnostic inspection and discovered condensate drain line issue with visible mineral deposits and buildup at drain connection point. Inspected attic space and ductwork, finding pink fiberglass insulation with signs of water damage and discoloration around affected area. Documented conditions with photographs showing deteriorated drain fitting with crusty residue accumulation and water-damaged insulation materials. Identified source of water intrusion coming from behind unit due to compromised condensate drainage system.
Vance P.
Vance P. Checked in
Responded to water leak complaint at indoor HVAC unit in sunroom that had been leaking for several days. Unit was off upon arrival. Performed diagnostic inspection and discovered condensate drain line issue with visible mineral deposits and buildup at drain connection point. Inspected attic space and ductwork, finding pink fiberglass insulation with signs of water damage and discoloration around affected area. Documented conditions with photographs showing deteriorated drain fitting with crusty residue accumulation and water-damaged insulation materials. Identified source of water intrusion coming from behind unit due to compromised condensate drainage system.
Lexington, KY 40515
Replaced a leaking indoor coil on a Daikin wall-mounted mini split head unit covered under the manufacturer's 12-year parts warranty. Recovered remaining R-410A refrigerant from the system, installed the factory-ordered replacement coil, and performed a complete pressure test to verify system integrity. Evacuated the refrigerant system to manufacturer specifications and recharged with new R-410A refrigerant to proper operating levels.
Replaced a leaking indoor coil on a Daikin wall-mounted mini split head unit covered under the manufacturer's 12-year parts warranty. Recovered remaining R-410A refrigerant from the system, installed the factory-ordered replacement coil, and performed a complete pressure test to verify system integrity. Evacuated the refrigerant system to manufacturer specifications and recharged with new R-410A refrigerant to proper operating levels.
Matt T.
Matt T. Checked in
Replaced a leaking indoor coil on a Daikin wall-mounted mini split head unit covered under the manufacturer's 12-year parts warranty. Recovered remaining R-410A refrigerant from the system, installed the factory-ordered replacement coil, and performed a complete pressure test to verify system integrity. Evacuated the refrigerant system to manufacturer specifications and recharged with new R-410A refrigerant to proper operating levels.
Lexington, KY 40509
Conducted electrical estimate for basement GFCI outlet issues reported as frequently tripping. Inspected multiple ground fault circuit interrupter receptacles throughout basement area to assess condition and functionality. Documented existing electrical infrastructure including thermostat controls and mechanical room equipment to determine scope of GFCI replacement work needed.
Conducted electrical estimate for basement GFCI outlet issues reported as frequently tripping. Inspected multiple ground fault circuit interrupter receptacles throughout basement area to assess condition and functionality. Documented existing electrical infrastructure including thermostat controls and mechanical room equipment to determine scope of GFCI replacement work needed.
Exavier S.
Exavier S. Checked in
Conducted electrical estimate for basement GFCI outlet issues reported as frequently tripping. Inspected multiple ground fault circuit interrupter receptacles throughout basement area to assess condition and functionality. Documented existing electrical infrastructure including thermostat controls and mechanical room equipment to determine scope of GFCI replacement work needed.
Lexington, KY 40502
Responded to no-cooling call for 2-year-old residential air conditioning system with complete power loss to control panel. Upon arrival, confirmed total loss of power to unit and black control panel display affecting entire home's cooling capacity. Performed diagnostic temperature measurements of evaporator coil, recording 31.9°F at coil surface, and measured supply air temperature differential of 5.96°F at ductwork to assess system performance once power was restored. Investigated electrical supply, control board connections, and safety circuits to identify cause of power failure. Verified proper refrigerant temperatures and system operation following repairs. System restored to normal operation with appropriate cooling capacity and control panel functionality confirmed.
Responded to no-cooling call for 2-year-old residential air conditioning system with complete power loss to control panel. Upon arrival, confirmed total loss of power to unit and black control panel display affecting entire home's cooling capacity. Performed diagnostic temperature measurements of evaporator coil, recording 31.9°F at coil surface, and measured supply air temperature differential of 5.96°F at ductwork to assess system performance once power was restored. Investigated electrical supply, control board connections, and safety circuits to identify cause of power failure. Verified proper refrigerant temperatures and system operation following repairs. System restored to normal operation with appropriate cooling capacity and control panel functionality confirmed.
Carter B.
Carter B. Checked in
Responded to no-cooling call for 2-year-old residential air conditioning system with complete power loss to control panel. Upon arrival, confirmed total loss of power to unit and black control panel display affecting entire home's cooling capacity. Performed diagnostic temperature measurements of evaporator coil, recording 31.9°F at coil surface, and measured supply air temperature differential of 5.96°F at ductwork to assess system performance once power was restored. Investigated electrical supply, control board connections, and safety circuits to identify cause of power failure. Verified proper refrigerant temperatures and system operation following repairs. System restored to normal operation with appropriate cooling capacity and control panel functionality confirmed.
Lexington, KY 40509
Responded to service call for Rheem Classic 50-gallon electric water heater (model PROE50 M2 RH95) with inadequate hot water duration. Upon arrival, performed diagnostic evaluation of unit installed in 2023. Inspected electrical connections, thermostat settings, and heating element functionality. Tested temperature and pressure relief valve operation and verified proper copper piping connections with ball valve shut-off. Assessed upper and lower heating elements for continuity and proper resistance values. Checked thermostat calibration and temperature settings on both upper and lower units. Evaluated sediment accumulation and tank condition. Confirmed unit remains under manufacturer's 10-year tank warranty. Documented findings with photographic evidence showing complete installation including copper piping configuration, electrical conduit, and overall system condition.
Responded to service call for Rheem Classic 50-gallon electric water heater (model PROE50 M2 RH95) with inadequate hot water duration. Upon arrival, performed diagnostic evaluation of unit installed in 2023. Inspected electrical connections, thermostat settings, and heating element functionality. Tested temperature and pressure relief valve operation and verified proper copper piping connections with ball valve shut-off. Assessed upper and lower heating elements for continuity and proper resistance values. Checked thermostat calibration and temperature settings on both upper and lower units. Evaluated sediment accumulation and tank condition. Confirmed unit remains under manufacturer's 10-year tank warranty. Documented findings with photographic evidence showing complete installation including copper piping configuration, electrical conduit, and overall system condition.
Shaun H.
Shaun H. Checked in
Responded to service call for Rheem Classic 50-gallon electric water heater (model PROE50 M2 RH95) with inadequate hot water duration. Upon arrival, performed diagnostic evaluation of unit installed in 2023. Inspected electrical connections, thermostat settings, and heating element functionality. Tested temperature and pressure relief valve operation and verified proper copper piping connections with ball valve shut-off. Assessed upper and lower heating elements for continuity and proper resistance values. Checked thermostat calibration and temperature settings on both upper and lower units. Evaluated sediment accumulation and tank condition. Confirmed unit remains under manufacturer's 10-year tank warranty. Documented findings with photographic evidence showing complete installation including copper piping configuration, electrical conduit, and overall system condition.
Lexington, KY 40509
Completed comprehensive Care Plan tune-up on air conditioning system with gas furnace located in basement. Performed standard maintenance protocol including inspection of ductwork, filter replacement with customer-supplied 16x25x1 filter, and system diagnostics. Evaluated outdoor condensing unit, verified electrical connections, and measured amperage draw at 5.67 amps using clamp meter, confirming unit operating within manufacturer specifications. Inspected capacitor, compressor, and all electrical components for proper function. System tested and operating efficiently with no issues identified.
Completed comprehensive Care Plan tune-up on air conditioning system with gas furnace located in basement. Performed standard maintenance protocol including inspection of ductwork, filter replacement with customer-supplied 16x25x1 filter, and system diagnostics. Evaluated outdoor condensing unit, verified electrical connections, and measured amperage draw at 5.67 amps using clamp meter, confirming unit operating within manufacturer specifications. Inspected capacitor, compressor, and all electrical components for proper function. System tested and operating efficiently with no issues identified.
Gideon J.
Gideon J. Checked in
Completed comprehensive Care Plan tune-up on air conditioning system with gas furnace located in basement. Performed standard maintenance protocol including inspection of ductwork, filter replacement with customer-supplied 16x25x1 filter, and system diagnostics. Evaluated outdoor condensing unit, verified electrical connections, and measured amperage draw at 5.67 amps using clamp meter, confirming unit operating within manufacturer specifications. Inspected capacitor, compressor, and all electrical components for proper function. System tested and operating efficiently with no issues identified.
Lexington, KY 40502
Completed toilet tank rebuild service. Removed and replaced all internal flush mechanisms including fill valve assembly with red-capped actuator, flapper valve with rubber seal, and overflow tube connections. Installed new components, adjusted water level settings, tested flush operation for proper function, and verified tank refill cycle operating within normal parameters.
Completed toilet tank rebuild service. Removed and replaced all internal flush mechanisms including fill valve assembly with red-capped actuator, flapper valve with rubber seal, and overflow tube connections. Installed new components, adjusted water level settings, tested flush operation for proper function, and verified tank refill cycle operating within normal parameters.
Shaun H.
Shaun H. Checked in
Completed toilet tank rebuild service. Removed and replaced all internal flush mechanisms including fill valve assembly with red-capped actuator, flapper valve with rubber seal, and overflow tube connections. Installed new components, adjusted water level settings, tested flush operation for proper function, and verified tank refill cycle operating within normal parameters.
Lexington, KY 40509
Lexington, KY - Completed routine plumbing preventative service agreement inspection of residential water heating system. Documented Bradford White 50-gallon natural gas water heater (Model RG250T6N) specifications and verified proper labeling, including all safety certifications, operating parameters, and installation clearance requirements are present and legible for future reference.
Shaun H.
Shaun H. Checked in
Completed routine plumbing preventative service agreement inspection of residential water heating system. Documented Bradford White 50-gallon natural gas water heater (Model RG250T6N) specifications and verified proper labeling, including all safety certifications, operating parameters, and installation clearance requirements are present and legible for future reference.
Lexington, KY 40515
Completed scheduled air conditioning tune-up under Club Green preventive maintenance agreement. Performed comprehensive system inspection, changed air filters with customer-supplied replacements (16x25x4), and inspected blower motor compartment which showed evidence of previous moisture intrusion with visible staining on interior cabinet surfaces. All operational components tested and system operating within normal parameters at time of service completion.
Completed scheduled air conditioning tune-up under Club Green preventive maintenance agreement. Performed comprehensive system inspection, changed air filters with customer-supplied replacements (16x25x4), and inspected blower motor compartment which showed evidence of previous moisture intrusion with visible staining on interior cabinet surfaces. All operational components tested and system operating within normal parameters at time of service completion.
Matt B.
Matt B. Checked in
Completed scheduled air conditioning tune-up under Club Green preventive maintenance agreement. Performed comprehensive system inspection, changed air filters with customer-supplied replacements (16x25x4), and inspected blower motor compartment which showed evidence of previous moisture intrusion with visible staining on interior cabinet surfaces. All operational components tested and system operating within normal parameters at time of service completion.
Lexington, KY 40514
Responded to water leak complaint with water streaming down wall from attic causing drywall separation at seam. Upon inspection of attic-mounted HVAC system, photographed equipment and surrounding area to document conditions. Attic space showed exposed framing with spray foam insulation, metallic ductwork with reflective insulation, and air handler unit with connected flexible ducting. OSB wall sheathing exhibited greenish discoloration indicating moisture staining or potential mold growth. Documented all findings with photographic evidence for further evaluation and repair recommendations.
Responded to water leak complaint with water streaming down wall from attic causing drywall separation at seam. Upon inspection of attic-mounted HVAC system, photographed equipment and surrounding area to document conditions. Attic space showed exposed framing with spray foam insulation, metallic ductwork with reflective insulation, and air handler unit with connected flexible ducting. OSB wall sheathing exhibited greenish discoloration indicating moisture staining or potential mold growth. Documented all findings with photographic evidence for further evaluation and repair recommendations.
Vance P.
Vance P. Checked in
Responded to water leak complaint with water streaming down wall from attic causing drywall separation at seam. Upon inspection of attic-mounted HVAC system, photographed equipment and surrounding area to document conditions. Attic space showed exposed framing with spray foam insulation, metallic ductwork with reflective insulation, and air handler unit with connected flexible ducting. OSB wall sheathing exhibited greenish discoloration indicating moisture staining or potential mold growth. Documented all findings with photographic evidence for further evaluation and repair recommendations.
Lexington, KY 40514
Completed full residential HVAC system replacement including installation of Trane 100K BTU two-stage 97% efficiency gas furnace (model S9V2C100U5VSBB), Trane 5-ton 14.3 SEER2 air conditioning unit (model 5TTR4060A1000A), matching evaporator coil (model 5TXCCOO7AS3HCA), and digital thermostat. Removed existing equipment and disposed of properly, then installed bottom base box to ensure proper airflow for the AC unit. Removed old humidifier and patched penetration hole in ductwork. Installed outdoor condenser unit on new concrete pad with gravel packed between and around pavers to eliminate hollow spots and ensure stable, level support. Connected refrigerant lines with proper insulation, installed electrical whip kit and disconnect box at outdoor unit, and ran electrical conduit along exterior wall. Installed flexible gas line connector with gas shut-off switch, connected to flue piping with proper transitions, and added flame roll-out protection. Installed electrical shut-off switch, s
Completed full residential HVAC system replacement including installation of Trane 100K BTU two-stage 97% efficiency gas furnace (model S9V2C100U5VSBB), Trane 5-ton 14.3 SEER2 air conditioning unit (model 5TTR4060A1000A), matching evaporator coil (model 5TXCCOO7AS3HCA), and digital thermostat. Removed existing equipment and disposed of properly, then installed bottom base box to ensure proper airflow for the AC unit. Removed old humidifier and patched penetration hole in ductwork. Installed outdoor condenser unit on new concrete pad with gravel packed between and around pavers to eliminate hollow spots and ensure stable, level support. Connected refrigerant lines with proper insulation, installed electrical whip kit and disconnect box at outdoor unit, and ran electrical conduit along exterior wall. Installed flexible gas line connector with gas shut-off switch, connected to flue piping with proper transitions, and added flame roll-out protection. Installed electrical shut-off switch, s
Cade R.
Cade R. Checked in
Completed full residential HVAC system replacement including installation of Trane 100K BTU two-stage 97% efficiency gas furnace (model S9V2C100U5VSBB), Trane 5-ton 14.3 SEER2 air conditioning unit (model 5TTR4060A1000A), matching evaporator coil (model 5TXCCOO7AS3HCA), and digital thermostat. Removed existing equipment and disposed of properly, then installed bottom base box to ensure proper airflow for the AC unit. Removed old humidifier and patched penetration hole in ductwork. Installed outdoor condenser unit on new concrete pad with gravel packed between and around pavers to eliminate hollow spots and ensure stable, level support. Connected refrigerant lines with proper insulation, installed electrical whip kit and disconnect box at outdoor unit, and ran electrical conduit along exterior wall. Installed flexible gas line connector with gas shut-off switch, connected to flue piping with proper transitions, and added flame roll-out protection. Installed electrical shut-off switch, s
Lexington, KY 40503

Why GreenBox?

We Pride Ourselves On Friendly, Honest Customer Service

Craftsmanship Guaranteed

We will do what it takes to ensure your satisfaction with the quality of your installation.

Emergency Service

Our live support team is available around the clock for emergency call intake and priority dispatch for your heating and cooling needs.

Upfront Pricing

You will know the cost of your service before we start any work.

365-Day Guarantee

If a system installed by us doesn't meet your needs after one year, we will refund you 100%.

Same-Day Installation

We can install your new heating or cooling system in as little as one day.

Free In-Home Estimate

We want your service to be easy and convenient, so we offer free estimates.

Craftsmanship Guaranteed

We will do what it takes to ensure your satisfaction with the quality of your installation.

Emergency Service

Our live support team is available around the clock for emergency call intake and priority dispatch for your heating and cooling needs.

Upfront Pricing

You will know the cost of your service before we start any work.

365-Day Guarantee

If a system installed by us doesn't meet your needs after one year, we will refund you 100%.

Same-Day Installation

We can install your new heating or cooling system in as little as one day.

Free In-Home Estimate

We want your service to be easy and convenient, so we offer free estimates.

Review Image

What Our Clients Are Saying

I am very impressed by the customer service I received at GreenBox. The person answering my call was kind and had a sense of urgency to address my need. I appreciated the text correspondence and the ability to coordinate timing of the technician’s visit. It was…

Amy W.

Amy W.

I was so impressed with with David. He was so knowledgeable and helped me make the best decision for me. The installation was done quickly and professionally. I am so very happy that I went with GreenBox. I would highly recommend you business to family and…

Linda M.

Linda M.

Fantastic service helped me within a hour I can’t say enough good things about Matt and GreenBox thanks again!!!!!!!

Joey T.

Joey T.

Love GreenBox!! Always professional. Very knowledgeable. Hard working, fair, courteous, clean and just good!

Kelly S.

Kelly S.

Great customer service and value. The technician Robert Caudill called ahead of time as requested and did a great job. Would definitely recommend GreenBox to anyone needing service or sales!

Chad M.

Chad M.