Expert Plumbing Services & Contractors in Lexington, KY
Emergency Service
<p>Unforeseen HVAC or plumbing issues can disrupt your comfort at times. Our Emergency Service guarantees swift attention. Day or night, reach out for immediate resolution, ensuring your home or business stays comfortable and functional, providing you with peace of mind around the clock. Give us a call at (859) 278-0281.</p>

Top-Rated Plumbing in Lexington, KY

frozen pipe

The plumbing in your Lexington, KY, home is its backbone. From hot showers to moving waste away from your home, you need it to work to keep your home functioning. The team at GreenBox Home Services is ready to help you with all your plumbing needs. Let us show you our commitment to customer service and quality work. We offer same-day service, upfront pricing, and financing options.

Why Choose GreenBox Home Services?

GreenBox Home Services is ready to help regardless of your problem. Our fully licensed, insured, and certified team has the skills and experience to solve your plumbing issue. We’re dedicated to building relationships through exceptional customer service, attention to detail, and affordable pricing. We back our work with our Quality of Service Guarantee. You can trust we’ll do the job right the first time. Call GreenBox Home Services at (859) 278-0281 or contact us online to schedule an appointment for any of your plumbing needs.

Same-Day Plumbing Repair in Lexington

When you need reliable plumbing repairs in Lexington, look no further than GreenBox Home Services. We’re the area experts in full-service plumbing solutions. Our services include:

For superior plumbing repair services in Lexington, choose GreenBox Home Services. Call us at (859) 278-0281 or contact us online today!

Expert Plumbing Installation in Lexington

If you need plumbing installation services in Lexington, our experts are ready to help! Their skills and experience mean your new plumbing will be beautiful and functional. Count on us for:

  • Faucets: If you want to change the aesthetic or replace a broken fixture, we can help you!
  • Sinks: A cracked sink is unsightly and can allow water to leak. Let us get your sink functioning again.
  • Garbage Disposals: Keep kitchen waste from collecting with a garbage disposal. We’ll help you choose one that fits your needs and home.
  • Plumbing Systems: It doesn’t matter if you need to redo a small section of your plumbing or a whole-house repiping. We will get the job done right the first time.

To schedule your plumbing installation service, call us at (859) 278-0281 or contact us online today!

Reliable Water Heaters

A working water heater is more than a luxury. You need it to work to clean your home and family. If you need water heater services in Lexington, we offer a full range of services, including:

Let us help you with your water heater needs in Lexington. Call GreenBox Home Services at (859) 278-0281 or contact us online to schedule your appointment.

Other Services

Part of keeping your Lexington home running smoothly is keeping all your plumbing systems working well. GreenBox Home Services is the area’s premier full-service plumbing company and offers solutions to all your plumbing needs. Our other services include:

For comprehensive plumbing services in Lexington, choose GreenBox Home Services. We’re ready to help you solve all your plumbing problems, both small and large! Call us at (859) 278-0281 or contact us online to schedule your appointment today!

Plumbing FAQs

Traditional tank water heaters are still the most popular option for homeowners. Their various sizes and relatively low entry-point cost make them an affordable and reliable option.

Yes! Professional plumbers do fix drains. They have the skills, experience, and equipment to precisely locate the problem and clear the drain without damaging your drain and sewer lines.

 

Recent Jobs and Reviews in Lexington, KY

Job Locations and Reviews

Completed comprehensive care plan tune-up on heat pump and air handler system located in closet with washable filter. Performed standard maintenance diagnostics using calibrated digital measurement equipment to assess system temperatures and operational parameters on supply ductwork and insulated refrigerant lines. Documented equipment conditions and verified proper system operation per manufacturer specifications.
Completed comprehensive care plan tune-up on heat pump and air handler system located in closet with washable filter. Performed standard maintenance diagnostics using calibrated digital measurement equipment to assess system temperatures and operational parameters on supply ductwork and insulated refrigerant lines. Documented equipment conditions and verified proper system operation per manufacturer specifications.
Carter B.
Carter B. Checked in
Completed comprehensive care plan tune-up on heat pump and air handler system located in closet with washable filter. Performed standard maintenance diagnostics using calibrated digital measurement equipment to assess system temperatures and operational parameters on supply ductwork and insulated refrigerant lines. Documented equipment conditions and verified proper system operation per manufacturer specifications.
Lexington, KY 40503
Lexington, KY - Conducted site assessment of crawl space for sump pump installation quote. Evaluated access conditions, existing drainage patterns, and identified optimal pump placement location while coordinating with electrical contractor for dedicated outlet installation requirements.
Caddo D.
Caddo D. Checked in
Conducted site assessment of crawl space for sump pump installation quote. Evaluated access conditions, existing drainage patterns, and identified optimal pump placement location while coordinating with electrical contractor for dedicated outlet installation requirements.
Lexington, KY 40511
Lexington, KY - Responded to emergency call for severely clogged toilet in accessible bathroom where previous plunging attempts and tank water removal had failed. Successfully diagnosed and cleared obstruction from toilet drain line using professional augering equipment. Restored full flushing function to the unit, which was the only operational commode in the residence.
Caddo D.
Caddo D. Checked in
Responded to emergency call for severely clogged toilet in accessible bathroom where previous plunging attempts and tank water removal had failed. Successfully diagnosed and cleared obstruction from toilet drain line using professional augering equipment. Restored full flushing function to the unit, which was the only operational commode in the residence.
Lexington, KY 40511
Responded to no cooling complaint on 2-year-old Rheem air conditioning system. Upon arrival, confirmed outdoor condenser fan was not operating while compressor attempted to run. Diagnosed failed condenser fan motor due to electrical failure. Replaced defective fan motor with OEM replacement part, verified proper rotation and amperage draw. Tested system operation through complete cooling cycle, confirmed adequate airflow across condenser coil and proper temperature split at indoor unit. System restored to normal cooling operation.
Responded to no cooling complaint on 2-year-old Rheem air conditioning system. Upon arrival, confirmed outdoor condenser fan was not operating while compressor attempted to run. Diagnosed failed condenser fan motor due to electrical failure. Replaced defective fan motor with OEM replacement part, verified proper rotation and amperage draw. Tested system operation through complete cooling cycle, confirmed adequate airflow across condenser coil and proper temperature split at indoor unit. System restored to normal cooling operation.
Andrew W.
Andrew W. Checked in
Responded to no cooling complaint on 2-year-old Rheem air conditioning system. Upon arrival, confirmed outdoor condenser fan was not operating while compressor attempted to run. Diagnosed failed condenser fan motor due to electrical failure. Replaced defective fan motor with OEM replacement part, verified proper rotation and amperage draw. Tested system operation through complete cooling cycle, confirmed adequate airflow across condenser coil and proper temperature split at indoor unit. System restored to normal cooling operation.
Lexington, KY 40515
Responded to no cooling complaint on 7-year-old electric heat pump system with outdoor unit not running and warm air from indoor unit. Upon arrival, confirmed thermostat set to cooling mode at 77 degrees with system calling for cooling but outdoor condenser remaining inoperative. Performed diagnostic inspection of outdoor unit, checking electrical connections, capacitor, contactor, and compressor components. Identified failed component preventing condenser operation and completed necessary repairs to restore system functionality. Verified proper operation of heat pump with outdoor unit running and cold air delivery at registers upon completion.
Responded to no cooling complaint on 7-year-old electric heat pump system with outdoor unit not running and warm air from indoor unit. Upon arrival, confirmed thermostat set to cooling mode at 77 degrees with system calling for cooling but outdoor condenser remaining inoperative. Performed diagnostic inspection of outdoor unit, checking electrical connections, capacitor, contactor, and compressor components. Identified failed component preventing condenser operation and completed necessary repairs to restore system functionality. Verified proper operation of heat pump with outdoor unit running and cold air delivery at registers upon completion.
Andrew W.
Andrew W. Checked in
Responded to no cooling complaint on 7-year-old electric heat pump system with outdoor unit not running and warm air from indoor unit. Upon arrival, confirmed thermostat set to cooling mode at 77 degrees with system calling for cooling but outdoor condenser remaining inoperative. Performed diagnostic inspection of outdoor unit, checking electrical connections, capacitor, contactor, and compressor components. Identified failed component preventing condenser operation and completed necessary repairs to restore system functionality. Verified proper operation of heat pump with outdoor unit running and cold air delivery at registers upon completion.
Lexington, KY 40509
Completed full HVAC system replacement in attic space, installing RUUD/Rheem 3-ton two-stage heat pump (model RP14AY36AJ2NA, 15.2 SEER2) as outdoor unit, RUUD/Rheem 3-ton air handler (model RH2TY3617STANNJ), and 15 KW heat kit (model RXBH-1724A15J-B). Removed and disposed of existing equipment per code requirements. Installed outdoor unit on new pad with snow legs, electrical disconnect box, and whip kit. Connected refrigerant lines between outdoor unit and air handler. Mounted air handler in attic space and integrated 15 KW supplemental heat kit for backup heating. Installed approximately 8 feet of duct board at damper locations to facilitate proper airflow distribution. Connected new system to existing zone control system and thermostats, maintaining multi-zone functionality throughout residence. Installed drain trap, SS2 coil drain safety water sensor, and "Ceiling Saver" overflow drain pan with water sensor for secondary condensate protection. Fabricated transitions to connect new
Completed full HVAC system replacement in attic space, installing RUUD/Rheem 3-ton two-stage heat pump (model RP14AY36AJ2NA, 15.2 SEER2) as outdoor unit, RUUD/Rheem 3-ton air handler (model RH2TY3617STANNJ), and 15 KW heat kit (model RXBH-1724A15J-B). Removed and disposed of existing equipment per code requirements. Installed outdoor unit on new pad with snow legs, electrical disconnect box, and whip kit. Connected refrigerant lines between outdoor unit and air handler. Mounted air handler in attic space and integrated 15 KW supplemental heat kit for backup heating. Installed approximately 8 feet of duct board at damper locations to facilitate proper airflow distribution. Connected new system to existing zone control system and thermostats, maintaining multi-zone functionality throughout residence. Installed drain trap, SS2 coil drain safety water sensor, and "Ceiling Saver" overflow drain pan with water sensor for secondary condensate protection. Fabricated transitions to connect new
Axel G.
Axel G. Checked in
Completed full HVAC system replacement in attic space, installing RUUD/Rheem 3-ton two-stage heat pump (model RP14AY36AJ2NA, 15.2 SEER2) as outdoor unit, RUUD/Rheem 3-ton air handler (model RH2TY3617STANNJ), and 15 KW heat kit (model RXBH-1724A15J-B). Removed and disposed of existing equipment per code requirements. Installed outdoor unit on new pad with snow legs, electrical disconnect box, and whip kit. Connected refrigerant lines between outdoor unit and air handler. Mounted air handler in attic space and integrated 15 KW supplemental heat kit for backup heating. Installed approximately 8 feet of duct board at damper locations to facilitate proper airflow distribution. Connected new system to existing zone control system and thermostats, maintaining multi-zone functionality throughout residence. Installed drain trap, SS2 coil drain safety water sensor, and "Ceiling Saver" overflow drain pan with water sensor for secondary condensate protection. Fabricated transitions to connect new
Lexington, KY 40502
Removed deteriorated sump pump system from existing basin and installed new submersible sump pump unit. The previous pump showed significant wear and corrosion, with mineral buildup evident throughout the basin and discharge piping. Completed full system replacement to restore proper groundwater drainage and basement protection functionality.
Removed deteriorated sump pump system from existing basin and installed new submersible sump pump unit. The previous pump showed significant wear and corrosion, with mineral buildup evident throughout the basin and discharge piping. Completed full system replacement to restore proper groundwater drainage and basement protection functionality.
Alec L.
Alec L. Checked in
Removed deteriorated sump pump system from existing basin and installed new submersible sump pump unit. The previous pump showed significant wear and corrosion, with mineral buildup evident throughout the basin and discharge piping. Completed full system replacement to restore proper groundwater drainage and basement protection functionality.
Lexington, KY 40502
Responded to service call for burst copper water line mounted vertically on exterior deck post. The line, which supplied a hose connection for cleaning the second-level deck, had frozen and ruptured during winter months. Upon arrival, water supply was confirmed off and damage was assessed. Documented existing installation showing copper pipe secured to deck post with mounting brackets. Discussed freeze protection options with property owner including pipe insulation, heat tape application, and installation of frost-free hose bib with proper drainage slope. Photographed damaged copper line and mounting configuration for replacement planning and future reference.
Responded to service call for burst copper water line mounted vertically on exterior deck post. The line, which supplied a hose connection for cleaning the second-level deck, had frozen and ruptured during winter months. Upon arrival, water supply was confirmed off and damage was assessed. Documented existing installation showing copper pipe secured to deck post with mounting brackets. Discussed freeze protection options with property owner including pipe insulation, heat tape application, and installation of frost-free hose bib with proper drainage slope. Photographed damaged copper line and mounting configuration for replacement planning and future reference.
Caddo D.
Caddo D. Checked in
Responded to service call for burst copper water line mounted vertically on exterior deck post. The line, which supplied a hose connection for cleaning the second-level deck, had frozen and ruptured during winter months. Upon arrival, water supply was confirmed off and damage was assessed. Documented existing installation showing copper pipe secured to deck post with mounting brackets. Discussed freeze protection options with property owner including pipe insulation, heat tape application, and installation of frost-free hose bib with proper drainage slope. Photographed damaged copper line and mounting configuration for replacement planning and future reference.
Lexington, KY 40515
Completed Gold Level prepaid maintenance service on dual Rheem condensing units at residential property. Performed comprehensive inspection of both outdoor units including visual assessment of condenser coils, fan assemblies, and electrical connections. Verified proper operation of compressors and condenser fan motors on both systems. Inspected refrigerant line sets and electrical conduit routing along building exterior. Checked mounting pads and clearances around equipment for proper airflow and accessibility.

Accessed indoor air handler unit and inspected evaporator coil insulation for integrity and signs of moisture infiltration. Examined internal wiring connections and control circuits. Verified insulation material condition and noted normal wear patterns consistent with system age and operation. Both systems operating within normal parameters with no immediate service needs identified. All components functioning as designed at time of inspection.
Completed Gold Level prepaid maintenance service on dual Rheem condensing units at residential property. Performed comprehensive inspection of both outdoor units including visual assessment of condenser coils, fan assemblies, and electrical connections. Verified proper operation of compressors and condenser fan motors on both systems. Inspected refrigerant line sets and electrical conduit routing along building exterior. Checked mounting pads and clearances around equipment for proper airflow and accessibility.

Accessed indoor air handler unit and inspected evaporator coil insulation for integrity and signs of moisture infiltration. Examined internal wiring connections and control circuits. Verified insulation material condition and noted normal wear patterns consistent with system age and operation. Both systems operating within normal parameters with no immediate service needs identified. All components functioning as designed at time of inspection.
Andrew W.
Andrew W. Checked in
Completed Gold Level prepaid maintenance service on dual Rheem condensing units at residential property. Performed comprehensive inspection of both outdoor units including visual assessment of condenser coils, fan assemblies, and electrical connections. Verified proper operation of compressors and condenser fan motors on both systems. Inspected refrigerant line sets and electrical conduit routing along building exterior. Checked mounting pads and clearances around equipment for proper airflow and accessibility. Accessed indoor air handler unit and inspected evaporator coil insulation for integrity and signs of moisture infiltration. Examined internal wiring connections and control circuits. Verified insulation material condition and noted normal wear patterns consistent with system age and operation. Both systems operating within normal parameters with no immediate service needs identified. All components functioning as designed at time of inspection.
Lexington, KY 40508
Returned to property to correct condensate discharge line routing to gutter as previously requested. Repositioned white PVC drainage piping along exterior brick wall, installing proper elbow fittings and horizontal run to direct discharge away from foundation and toward gutter system. Secured all piping with appropriate mounting brackets to ensure proper support and alignment, preventing future sagging or separation of joints.
Returned to property to correct condensate discharge line routing to gutter as previously requested. Repositioned white PVC drainage piping along exterior brick wall, installing proper elbow fittings and horizontal run to direct discharge away from foundation and toward gutter system. Secured all piping with appropriate mounting brackets to ensure proper support and alignment, preventing future sagging or separation of joints.
Logan C.
Logan C. Checked in
Returned to property to correct condensate discharge line routing to gutter as previously requested. Repositioned white PVC drainage piping along exterior brick wall, installing proper elbow fittings and horizontal run to direct discharge away from foundation and toward gutter system. Secured all piping with appropriate mounting brackets to ensure proper support and alignment, preventing future sagging or separation of joints.
Lexington, KY 40509
Responded to service call for ongoing system performance concerns and high indoor humidity complaints since 2020 installation. Upon arrival, verified thermostat settings and observed indoor temperature at 73°F with humidity reading at 53%, while outdoor conditions measured 78°F at 51% humidity. System was in wait mode during inspection, indicating normal cycle operation. Documented current environmental conditions using both thermostat display and independent weather monitoring equipment to establish baseline readings for humidity concerns. Advised customer on typical humidity levels and system performance parameters, confirming equipment is maintaining setpoint temperature as programmed.
Responded to service call for ongoing system performance concerns and high indoor humidity complaints since 2020 installation. Upon arrival, verified thermostat settings and observed indoor temperature at 73°F with humidity reading at 53%, while outdoor conditions measured 78°F at 51% humidity. System was in wait mode during inspection, indicating normal cycle operation. Documented current environmental conditions using both thermostat display and independent weather monitoring equipment to establish baseline readings for humidity concerns. Advised customer on typical humidity levels and system performance parameters, confirming equipment is maintaining setpoint temperature as programmed.
Braden B.
Braden B. Checked in
Responded to service call for ongoing system performance concerns and high indoor humidity complaints since 2020 installation. Upon arrival, verified thermostat settings and observed indoor temperature at 73°F with humidity reading at 53%, while outdoor conditions measured 78°F at 51% humidity. System was in wait mode during inspection, indicating normal cycle operation. Documented current environmental conditions using both thermostat display and independent weather monitoring equipment to establish baseline readings for humidity concerns. Advised customer on typical humidity levels and system performance parameters, confirming equipment is maintaining setpoint temperature as programmed.
Lexington, KY 40511
Completed annual Gold Level prepaid maintenance visit on a 26-year-old single system. Performed comprehensive system diagnostics using manifold gauges to check refrigerant pressures on outdoor heat pump unit. Measured system operating pressures with Yellow Jacket gauge set, confirming both high and low side readings were within acceptable parameters. Utilized Fieldpiece digital multimeter to verify electrical readings and system performance metrics. Confirmed proper filter size for the system during this first annual visit. Inspected outdoor unit housing and verified all warning labels were intact and legible. All diagnostic equipment readings indicated the aging system is currently operating within normal specifications for its age.
Completed annual Gold Level prepaid maintenance visit on a 26-year-old single system. Performed comprehensive system diagnostics using manifold gauges to check refrigerant pressures on outdoor heat pump unit. Measured system operating pressures with Yellow Jacket gauge set, confirming both high and low side readings were within acceptable parameters. Utilized Fieldpiece digital multimeter to verify electrical readings and system performance metrics. Confirmed proper filter size for the system during this first annual visit. Inspected outdoor unit housing and verified all warning labels were intact and legible. All diagnostic equipment readings indicated the aging system is currently operating within normal specifications for its age.
Matt B.
Matt B. Checked in
Completed annual Gold Level prepaid maintenance visit on a 26-year-old single system. Performed comprehensive system diagnostics using manifold gauges to check refrigerant pressures on outdoor heat pump unit. Measured system operating pressures with Yellow Jacket gauge set, confirming both high and low side readings were within acceptable parameters. Utilized Fieldpiece digital multimeter to verify electrical readings and system performance metrics. Confirmed proper filter size for the system during this first annual visit. Inspected outdoor unit housing and verified all warning labels were intact and legible. All diagnostic equipment readings indicated the aging system is currently operating within normal specifications for its age.
Lexington, KY 40503
Lexington, KY - Responded to no cooling complaint on outdoor AC unit. Diagnosed blown FRN-R 30 amp fuse at disconnect, indicating electrical fault or overcurrent condition. Replaced defective fuse and verified proper system operation with normal cooling restored.
Braden B.
Braden B. Checked in
Responded to no cooling complaint on outdoor AC unit. Diagnosed blown FRN-R 30 amp fuse at disconnect, indicating electrical fault or overcurrent condition. Replaced defective fuse and verified proper system operation with normal cooling restored.
Lexington, KY 40503
Lexington, KY - Completed comprehensive Care Plan tune-up on dual heat pump and air handler system with units located in basement and crawl space. Performed standard maintenance protocol including electrical testing and capacitor diagnostics, with measured capacitance reading of 70.3 on the motor run capacitor (TITAN PRO TRCFD7075, 70+5 MFD rated at 370 VAC), confirming proper system operation. Customer provides own filters for ongoing maintenance.
Matt B.
Matt B. Checked in
Completed comprehensive Care Plan tune-up on dual heat pump and air handler system with units located in basement and crawl space. Performed standard maintenance protocol including electrical testing and capacitor diagnostics, with measured capacitance reading of 70.3 on the motor run capacitor (TITAN PRO TRCFD7075, 70+5 MFD rated at 370 VAC), confirming proper system operation. Customer provides own filters for ongoing maintenance.
Lexington, KY 40502
Responded to water leak complaint at sink in sterilization room. Inspected foot pedal assembly and confirmed intermittent leak caused by broken foot pedal mechanism. Documented existing plumbing configuration including P-trap assembly, supply lines, and manifold connections beneath sink. Part will be staged in warehouse for subsequent installation to resolve leak issue.
Responded to water leak complaint at sink in sterilization room. Inspected foot pedal assembly and confirmed intermittent leak caused by broken foot pedal mechanism. Documented existing plumbing configuration including P-trap assembly, supply lines, and manifold connections beneath sink. Part will be staged in warehouse for subsequent installation to resolve leak issue.
Nic Q.
Nic Q. Checked in
Responded to water leak complaint at sink in sterilization room. Inspected foot pedal assembly and confirmed intermittent leak caused by broken foot pedal mechanism. Documented existing plumbing configuration including P-trap assembly, supply lines, and manifold connections beneath sink. Part will be staged in warehouse for subsequent installation to resolve leak issue.
Lexington, KY 40503
Lexington, KY - Responded to service call for sewer line issues including backups, slow drains, and odors throughout the plumbing system. Performed sewer camera inspection to assess line condition and identify blockages or damage. Documented findings with photographic evidence of property bathroom facilities. Provided comprehensive quote for plumbing system upgrades and modernization as requested.
Alec L.
Alec L. Checked in
Responded to service call for sewer line issues including backups, slow drains, and odors throughout the plumbing system. Performed sewer camera inspection to assess line condition and identify blockages or damage. Documented findings with photographic evidence of property bathroom facilities. Provided comprehensive quote for plumbing system upgrades and modernization as requested.
Lexington, KY 40503
Completed comprehensive air conditioning tune-up and performance evaluation on gas furnace system located in basement as part of preventative maintenance care plan. Utilized Fieldpiece SC440 clamp meter to measure electrical parameters including capacitance readings of 493 MFD, verifying proper compressor and fan motor operation. Recorded supply air temperature of 53.5°F at the evaporator coil to confirm adequate cooling performance and refrigerant charge levels within manufacturer specifications.
Completed comprehensive air conditioning tune-up and performance evaluation on gas furnace system located in basement as part of preventative maintenance care plan. Utilized Fieldpiece SC440 clamp meter to measure electrical parameters including capacitance readings of 493 MFD, verifying proper compressor and fan motor operation. Recorded supply air temperature of 53.5°F at the evaporator coil to confirm adequate cooling performance and refrigerant charge levels within manufacturer specifications.
Carter B.
Carter B. Checked in
Completed comprehensive air conditioning tune-up and performance evaluation on gas furnace system located in basement as part of preventative maintenance care plan. Utilized Fieldpiece SC440 clamp meter to measure electrical parameters including capacitance readings of 493 MFD, verifying proper compressor and fan motor operation. Recorded supply air temperature of 53.5°F at the evaporator coil to confirm adequate cooling performance and refrigerant charge levels within manufacturer specifications.
Lexington, KY 40503
Completed spring preventative maintenance on 6-year-old air conditioning system with no reported issues. Performed comprehensive tune-up including inspection of condensate drain lines in attic space, verified proper drainage flow through PVC piping system, checked flexible ductwork for integrity and proper connection, and conducted diagnostic measurements using digital testing equipment. All components found operating within normal parameters, system ready for cooling season.
Completed spring preventative maintenance on 6-year-old air conditioning system with no reported issues. Performed comprehensive tune-up including inspection of condensate drain lines in attic space, verified proper drainage flow through PVC piping system, checked flexible ductwork for integrity and proper connection, and conducted diagnostic measurements using digital testing equipment. All components found operating within normal parameters, system ready for cooling season.
Matt T.
Matt T. Checked in
Completed spring preventative maintenance on 6-year-old air conditioning system with no reported issues. Performed comprehensive tune-up including inspection of condensate drain lines in attic space, verified proper drainage flow through PVC piping system, checked flexible ductwork for integrity and proper connection, and conducted diagnostic measurements using digital testing equipment. All components found operating within normal parameters, system ready for cooling season.
Lexington, KY 40511
Completed annual care plan maintenance on air conditioning system with gas furnace located in attic space. Performed comprehensive tune-up inspection of indoor air handler unit, checking all operational components, electrical connections, and airflow systems. Verified proper operation of blower motor and examined ductwork connections for secure mounting and adequate insulation. Inspected outdoor Lennox condenser unit, noting significant fire or heat damage to surrounding area including charred material on adjacent trash receptacle and thermal damage to vinyl siding near electrical connection point. Documented damaged and displaced paver stones around equipment pad. Despite external environmental damage, confirmed AC unit operational functionality and proper refrigerant levels. Customer provided air filters as specified in service agreement, which were installed per manufacturer specifications.
Completed annual care plan maintenance on air conditioning system with gas furnace located in attic space. Performed comprehensive tune-up inspection of indoor air handler unit, checking all operational components, electrical connections, and airflow systems. Verified proper operation of blower motor and examined ductwork connections for secure mounting and adequate insulation. Inspected outdoor Lennox condenser unit, noting significant fire or heat damage to surrounding area including charred material on adjacent trash receptacle and thermal damage to vinyl siding near electrical connection point. Documented damaged and displaced paver stones around equipment pad. Despite external environmental damage, confirmed AC unit operational functionality and proper refrigerant levels. Customer provided air filters as specified in service agreement, which were installed per manufacturer specifications.
Andrew W.
Andrew W. Checked in
Completed annual care plan maintenance on air conditioning system with gas furnace located in attic space. Performed comprehensive tune-up inspection of indoor air handler unit, checking all operational components, electrical connections, and airflow systems. Verified proper operation of blower motor and examined ductwork connections for secure mounting and adequate insulation. Inspected outdoor Lennox condenser unit, noting significant fire or heat damage to surrounding area including charred material on adjacent trash receptacle and thermal damage to vinyl siding near electrical connection point. Documented damaged and displaced paver stones around equipment pad. Despite external environmental damage, confirmed AC unit operational functionality and proper refrigerant levels. Customer provided air filters as specified in service agreement, which were installed per manufacturer specifications.
Lexington, KY 40509
Performed comprehensive Club Trio maintenance on multiple HVAC systems including one AC/gas furnace unit, two heat pump/air handler combinations, and one heat pump/gas furnace system located in various zones throughout the property. Conducted complete system diagnostics using calibrated test equipment to verify proper refrigerant pressures, temperatures, and overall system performance on all outdoor condensing units. Inspected all accessible equipment in upstairs and downstairs bedrooms, garage, and crawl space, checking electrical connections, verifying proper airflow, and ensuring all safety controls were functioning correctly across all systems.
Performed comprehensive Club Trio maintenance on multiple HVAC systems including one AC/gas furnace unit, two heat pump/air handler combinations, and one heat pump/gas furnace system located in various zones throughout the property. Conducted complete system diagnostics using calibrated test equipment to verify proper refrigerant pressures, temperatures, and overall system performance on all outdoor condensing units. Inspected all accessible equipment in upstairs and downstairs bedrooms, garage, and crawl space, checking electrical connections, verifying proper airflow, and ensuring all safety controls were functioning correctly across all systems.
Jalen S.
Jalen S. Checked in
Performed comprehensive Club Trio maintenance on multiple HVAC systems including one AC/gas furnace unit, two heat pump/air handler combinations, and one heat pump/gas furnace system located in various zones throughout the property. Conducted complete system diagnostics using calibrated test equipment to verify proper refrigerant pressures, temperatures, and overall system performance on all outdoor condensing units. Inspected all accessible equipment in upstairs and downstairs bedrooms, garage, and crawl space, checking electrical connections, verifying proper airflow, and ensuring all safety controls were functioning correctly across all systems.
Lexington, KY 40503

Why GreenBox?

We Pride Ourselves On Friendly, Honest Customer Service

Craftsmanship Guaranteed

We will do what it takes to ensure your satisfaction with the quality of your installation.

Emergency Service

Our team is available around the clock for your heating and air conditioning emergencies.

Upfront Pricing

You will know the cost of your service before we start any work.

365-Day Guarantee

If a system installed by us doesn't meet your needs after one year, we will refund you 100%.

Same-Day Installation

We can install your new heating or cooling system in as little as one day.

Free In-Home Estimate

We want your service to be easy and convenient, so we offer free estimates.

Craftsmanship Guaranteed

We will do what it takes to ensure your satisfaction with the quality of your installation.

Emergency Service

Our team is available around the clock for your heating and air conditioning emergencies.

Upfront Pricing

You will know the cost of your service before we start any work.

365-Day Guarantee

If a system installed by us doesn't meet your needs after one year, we will refund you 100%.

Same-Day Installation

We can install your new heating or cooling system in as little as one day.

Free In-Home Estimate

We want your service to be easy and convenient, so we offer free estimates.

Review Image

What Our Clients Are Saying

Talk about quality service! These guys and gals are the best! I have their yearly service plan and it is well worth it. They are professional, friendly and tidy. They do such great work. I am customer for life. Braden came out today and was speedy…

Regina S.

Regina S.

They were able to send David out the day I called. He was very professional, polite, and was able to educate me on our issues. He was able to give us an on the spot quote and it was very much to my surprise a lot…

Adrienne F.

Adrienne F.

Glad I went with GreenBox! They were able to get me scheduled immediately and fixed up same day. Matt was helpful and easy to talk to. Will recommend and use again!

Theresa W.

Theresa W.

Great customer service and value. The technician Robert Caudill called ahead of time as requested and did a great job. Would definitely recommend GreenBox to anyone needing service or sales!

Chad M.

Chad M.

Love GreenBox!! Always professional. Very knowledgeable. Hard working, fair, courteous, clean and just good!

Kelly S.

Kelly S.